3.3.12ALARM SETTING

User’s Manual

<DELETE> and press <ENTER> to delete the selected character.

STEP7: When the setting is completed, move the cursor to <SAVE> and press <ENTER> to save.

3.3.12ALARM SETTING

The integrated high speed dome provides eight alarm inputs and two alarm outputs (N.O. and N.C) to connect alarm devices. With this function, dome will cooperates with alarm system to catch the event images. For wiring, please refer to the installation guide and/or qualified service personnel. Alarm parameters can be set on this page.

ALARM SETTING

 

ALARM PIN

1

ALARM SWITCH

OFF

ALARM TYPE

N.C.

ALARM ACTION

PRESET

PRESET POINT

001

DWELL TIME

ALWAY

EXIT

YES

ALARM PIN

The dome provides 8 alarm inputs and 2 outputs (1× N.O. and 1× N.C.). Select an alarm connector which you want to set its alarm-related parameters with this item, and then set its alarm-related parameters in Alarm Setting menu. For alarm pin definitions, please refer to section 2.6 Alarm Pin Definition or installation guide.

ALARM SWITCH

The item is used to enable or disable the selected alarm pin function. Use the left/right direction keys on the control keyboard to change the setting.

ALARM TYPE

There are two kinds of alarm types: Normal Open and Normal Close, which are illustrated as below. Select an alarm type that corresponds with the alarm application.