USB HID Keyboard Emulation Swipe Reader
RESULT CODE
This 
Value | Result Code  | Description  | 
0  | SUCCESS  | The command completed successfully.  | 
1  | FAILURE  | The command failed.  | 
2  | BAD_PARAMETER  | The command failed due to a bad  | 
  | 
  | parameter or command syntax error.  | 
GET AND SET PROPERTY COMMANDS
The Get Property command gets a property from the device. The Get Property command number is 0.
The Set Property command sets a property in the device. The Set Property command number is 1.
The Get and Set Property command data fields for the requests and responses are structured as follows:
Get Property Request Data:
Data Offset  | Value  | 
0  | Property ID  | 
Get Property Response Data:
Data Offset  | Value  | 
0 – n  | Property Value  | 
Set Property Request Data:
Data Offset  | Value  | 
0  | Property ID  | 
1 – n  | Property Value  | 
Set Property Response Data:
None
The result codes for the Get and Set Property commands can be any of the codes list in the generic result code table.
14