Elo TouchSystems ESY1529L manual LD9000 series, Functional Test

Models: ESY1529L

1 142
Download 142 pages 16.34 Kb
Page 121
Image 121

INSTALLATION GUIDE

LD9000 series

Serial Interface Customer Pole Displays

LD9000, LD9200, LD9300, LD9400, LD9500 and LD9900

LD9000X, LD9200X, LD9300X, LD9400X, LD9500X and

LD9900X

INSTALLATION

Your LD9000 family of pole displays has been pre-assembled to make the installation as simple as possible.

1.Mount the pole display to the metal base plate using the mounting hardware provided.

2.The pole display can be used in a freestanding mode or attached to the counter using the remaining mounting hardware.

3.Connect the round DIN6M connector from the pole display to the round DIN6F connector of the interface cable.

4.Connect the DB9F connector to the computer’s serial COM1 or COM2 port.

5.Connect the female phone jack of the power adapter to the male phone jack of the interface cable.

6.Plug the power adapter into a 120VAC outlet.

7.A start up text message (LOGIC CONTROLS POS COMPONENTS) will be present for a short time. When this message disappears the cursor will be displayed at the left-most digit of the top row.

Serial Interface Connector Pinout

1.DCD (tied to pins 4&6)

2.NC

3.RXD from PC

4.DTR (tied to pins 1&6)

5.Ground

6.DSR (tied to pins 1&4)

7.

RTS (tied to pin 8)

DB9F (to computer)

8.CTS (tied to pin 7)

9.NC

FUNCTIONAL TEST

The following test sequence will verify that your pole display is working properly. Before you start this procedure, you must install the pole display correctly as outlined under the INSTALLATION section. The functional test should be done under MSDOS command prompt by booting up the computer in DOS mode, or shell out to DOS prompt (in Window95/98/ME) or COMMAND prompt (in Windows NT/2000).

NOTE: The actual key entries in the text below are enclosed within quotation marks ( “ ” ). Do not type the quotation marks as part of your entries.

This test procedure assumes the pole display is connected to COM1 of the computer. If COM2 is being used, type COM2 where COM1 is called out.

Close all opened application programs that use the same COM port before shelling out to DOS COMMAND prompt. Enter the following command lines to open the COM port for communication with the pole display:

Type “MODE COM1 96,N,8,1” and press the ENTER key. Type “TYPE CON>COM1” and press the ENTER key.

LD9000, LD9300, LD9400, LD9500, LD9900

1.Type “ABCDEFGH” and press ENTER key. The display will show “ABCDEFGH” on the first line.

2.To end the test press Ctrl-C (hold down Ctrl and press C).

LD9200

1.Type “!#1ABCDEFGH” and press ENTER key. The display will show “ABCDEFGH” on the first line.

2.To end the test press Ctrl-C (hold down Ctrl and press C).

User Manual available at our web site www.logiccontrols.com

Page 121