Precautions during Servicing

A.Parts identified by the ( #) symbol are critical for safety.

Replace only with part number specified.

B.In addition to safety, other parts and assemblies are specified for conformance with regulations ap- plying to spurious radiation. These must also be replaced only with specified replacements.

Examples: RF converters, RF cables, noise block- ing capacitors, and noise blocking filters, etc.

C.Use specified internal wiring. Note especially:

1)Wires covered with PVC tubing

2)Double insulated wires

3)High voltage leads

D.Use specified insulating materials for hazardous live parts. Note especially:

1)Insulation Tape

2)PVC tubing

3)Spacers

4)Insulators for transistors.

E.When replacing AC primary side components (transformers, power cord, etc.), wrap ends of wires securely about the terminals before solder- ing.

F.Observe that the wires do not contact heat produc- ing parts (heatsinks, oxide metal film resistors, fus- ible resistors, etc.)

G.Check that replaced wires do not contact sharp edged or pointed parts.

H.When a power cord has been replaced, check that 5~6 kg of force in any direction will not loosen it.

I.Also check areas surrounding repaired locations.

J.Use care that foreign objects (screws, solder drop- lets, etc.) do not remain inside the set.

K.Crimp type wire connector

The power transformer uses crimp type connec- tors which connect the power cord and the primary side of the transformer. When replacing the trans- former, follow these steps carefully and precisely to prevent shock hazards.

Replacement procedure

1)Remove the old connector by cutting the wires at a point close to the connector.

Important: Do not re-use a connector (discard it).

2)Strip about 15 mm of the insulation from the ends of the wires. If the wires are stranded, twist the strands to avoid frayed conductors.

3)Align the lengths of the wires to be connected. In- sert the wires fully into the connector.

4)Use the crimping tool to crimp the metal sleeve at the center position. Be sure to crimp fully to the complete closure of the tool.

L.When connecting or disconnecting the internal connectors, first, disconnect the AC plug from the AC supply outlet.

2-3

L6115IMP

Page 6
Image 6
Emerson 6420FE service manual Precautions during Servicing

6420FE specifications

The Emerson 6420FE is a robust and versatile platform designed for a variety of industrial applications, particularly in process automation, manufacturing, and control systems. This model represents Emerson’s commitment to innovation and performance, catering to the evolving needs of industries that require reliable and accurate control solutions.

One of the main features of the Emerson 6420FE is its advanced processing capability. Equipped with a high-performance processor, the device ensures fast data processing and response times, which are critical in real-time control environments. This allows organizations to optimize their processes, enhance productivity, and improve operational efficiency.

Connectivity is another standout characteristic of the Emerson 6420FE. It supports a range of communication protocols, including Ethernet/IP, Modbus, and others, enabling seamless integration with various devices and systems. This flexibility ensures that the 6420FE can be easily incorporated into existing networks, facilitating smooth data exchange and interoperability among different automation components.

In terms of safety, the Emerson 6420FE is designed with features that ensure compliance with industry standards. It includes built-in redundancy options that enhance operational reliability and minimize downtime. Moreover, the device undergoes rigorous testing to meet safety certifications, providing peace of mind to operators and stakeholders.

The user interface of the Emerson 6420FE is intuitive and user-friendly, featuring an easy-to-navigate design that simplifies configuration and operation. This is paired with advanced diagnostic capabilities, allowing operators to troubleshoot issues effectively and maintain optimal system performance without significant downtime.

Another notable aspect of the Emerson 6420FE is its scalability. Whether in a small application or a large-scale industrial environment, the device can be easily scaled to meet varying demands. This adaptability makes it an ideal solution for companies looking to future-proof their automation systems.

In conclusion, the Emerson 6420FE is a powerful and reliable device that embodies Emerson’s commitment to innovation in process control and automation. With its advanced processing power, versatile connectivity options, robust safety features, user-friendly interface, and scalability, it stands out as an excellent choice for industries looking to enhance their operational efficiencies and ensure streamlined processes. As technology continues to evolve, the Emerson 6420FE remains a cornerstone in automation solutions, driving productivity and reliability in various industrial applications.