ELECTRICAL ADJUSTMENT INSTRUCTIONS
General Note:
"CBA" is abbreviation for "Circuit Board Assem- bly."
NOTE:
Electrical adjustments are required after replacing circuit components and certain mechanical parts. It is important to perform these adjustments only after all repairs and replacements have been com- pleted.
Also, do not attempt these adjustments unless the proper equipment is available.
Test Equipment Required
1.NTSC Pattern Generator (Color Bar W/White Window, Red Color, Dot Pattern, Gray Scale, Monoscope,
2.DC Voltmeter
3.Oscilloscope:
4.Plastic Tip Driver
5.Remote control unit: Part No. NE122UD
6.DC power supply 13.2V/5A
How to make Service remote control unit:
1.Prepare normal remote control unit. (Part No. NE122UD
(Part No. NE154UD, NE142UD, N0108UD, N0132UD, NE116UD, NE153UD, NE141UD, NE122UD, or NE121UD
Remove 3 Screws from the back lid. (Fig.
2.Added J1 (Jumper Wire) to the remote control CBA. (Fig.
SCREWS
How to set up the service mode:
Service mode:
1.Use the service remote control unit.
2.Turn the power on. (Use main power on the TV unit.)
3.Press "SLEEP" button on the service remote con- trol unit. Version of micro computer will display on the CRT. (Ex:
4.Check the display on the lower left is "2641" and if it is not "2641," set it at "2641" according to "2. Ini- tial Setting."
1.+B Adjustment
Purpose: To obtain correct operation.
Symptom of Misadjustment: The picture is dark and the unit does not operate correctly.
Test Point | Adj. Point | Mode |
| Input |
|
|
|
|
|
|
|
|
|
|
TP601(+B) | VR661 |
| ||
TP300(GND) |
| |||
|
|
|
| |
|
|
|
|
|
Tape | M. EQ. |
| Spec. | |
|
|
| ||
DC Voltmeter | +114±0.5V DC. | |||
|
|
|
|
|
Note: TP601, TP300(GND), VR661
1.Connect DC Volt Meter to TP601 and TP300(GND).
2.Adjust VR661 so that the voltage of TP601 becomes +114±0.5V DC.
REMOTE CONTROL UNIT | Fig. | |||
|
|
|
|
|
J 1 |
|
|
| Fig. |
| ||||
REMOTE CONTROL CBA | ||||
|
|
|
|
|
L2401EA |