IMPORTANT: Your ceiling fan is supplied with an SW116 Fan/Light Wall Control (transmitter) and a remote control SW105 Receiver which mounts under the ceiling cover. This system allows you to regulate your ceiling fan speed, airflow direction, and light intensity. An optional Emerson Electric SR110 Remote Control may also be used.

IMPORTANT: Your ceiling fan will not function properly and may be damaged, if used with any wall dimmer switch or control other than the Emerson controls listed above.

Electrical Requirements

Your new ceiling fan will require a grounded electrical supply line of 120 volts AC, 60 Hz, 15 amp circuit.

WARNING

To reduce the risk of fire, electric shock, or personal injury, mount fan to outlet box marked “Acceptable for Fan Support”, and use screws supplied with outlet box. Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced. Consult a qualified electrician if in doubt.

If your fan is to replace an existing ceiling light fixture, turn electricity off at the main fuse box at this time and remove the existing light fixture.

WARNING

Turning off wall switch is not sufficient. To avoid possible electrical shock, be sure electricity is turned off at the main fuse box before wiring. All wiring must be in accordance with national and local codes and the ceiling fan must be properly grounded as a precaution against possible electrical shock.

WARNING

To avoid possible fire or shock, follow all wiring instructions carefully. Any electrical work not described in these instructions should be done or approved by a licensed electrician.

Preliminary Procedures

IMPORTANT: Before assembling your ceiling fan, refer to sections “Setting Operating Frequency of Wall Control and Receiver” and “Installation of Wall Control”, Page 11. These sections instruct you how to:

a.Set the operating frequency of the fan/light wall control and the remote control receiver.

b.Install the fan/light wall control in the wall box.

You will then be ready to proceed with the assembly and installation of your ceiling fan.

Ceiling Fan Assembly

Procedures

1.Place the flange assembly onto the blade. Place the flange medallion assembly into the three holes on the opposite side of the blade.

2.Secure the flange assembly and flange medallion to the blade using the three M5 x 12mm pan head screws and three lockwashers. Repeat for the four remaining blades. (Figure 1)

FLANGE

M5 x 12mm

ASSEMBLY

PAN HEAD SCREW

 

(3 Per Blade)

 

LOCKWASHER

 

(3 Per Blade)

 

BLADE

FLANGE

MEDALLION

Figure 1

3.Place the motor housing assembly onto the styrofoam for blade assembly installation.

4.Align the holes in the blade flange assembly with the holes in the motor housing.

NOTE: Take care not to scratch fan housing when installing blades.

WARNING

To reduce the risk of personal injury, do not bend the blade flange when installing the blade flanges, balancing the blades or cleaning the fan. Do not insert foreign objects in between rotating fan blades.

5.Loosely attach the flange assembly using two #10-32 x 14mm oval head screws (supplied) (Figure 2). Install the remaining four fan blades assemblies using the same procedure.

6.Gently snug all flange screws to the motor housing, working around the housing in a clockwise sequence. Next, securely tighten all flange screws, again working in a clockwise sequence. Failure to follow this procedure could result in fan wobble. This completes the blade installation.

10-32 x 14mm

 

OVAL HEAD SCREW

 

(2 Per Blade)

MOTOR

FLANGE

HOUSING

 

ASSEMBLY

 

Figure 2

4

 

U.L. Model No.: CF3100

 

 

Page 4