the clevis pin. The hairpin clip must be properly installed to prevent the clevis pin from working loose. Pull on the downrod to make sure the clevis pin is properly installed.

11. Install the 5/16-18 x 1/4” setscrew into the threaded hole on the motor coupling.

!WARNING

It is critical that the clevis pin in the motor coupling is properly installed and the setscrew securely tightened. Failure to verify that the pin and setscrew are properly installed (as shown in Figure 4) could result in the fan falling.

12. While pulling up on the downrod, securely tighten the 5/16-18 x 1/4” setscrew (supplied) in the motor coupling using the 3/16” hex wrench (supplied) (Figure 5).

NOTE: The setscrew must be properly installed as described above, or fan wobble could result.

NOTE: Be careful not to scratch the downrod with the ceiling cover during installation.

#8-32 x 1/4" PAN HEAD SCREW (4)

MOTOR

COVER

FAN MOTOR

 

ASSEMBLY

DOWNROD

 

Figure 6

HAIRPIN CLIP

14. Make sure the grommet is properly installed in the coupling cover then slide the coupling cover over the downrod until it rests on the motor housing cover. Place the ceiling cover over the downrod. Be sure both the ceiling cover and the coupler cover are oriented correctly (Figure 7).

MOTOR

CLEVIS PIN

COUPLING

 

5/16-18 x 1/4"

SETSCREW

CEILING

COVER

DOWNROD

Figure 5

GROMMET

13. Carefully place the motor housing cover over the downrod the guide it over the motor housing assembly. Align the three mounting holes with the corresponding threaded holes on top of the motor. Install three #8-32 x 1/4” pan head screws into the holes to secure the motor cover (Figure 6).

COUPLING COVER

MOTOR

COVER

7 Figure 7