BP7384 Camden, CF3600 2/18/09 2:57 PM Page 14
! WARNING: FOR YOUR OWN SAFETY TURN OFF POWER AT FUSE BOX OR CIRCUIT BREAKER BEFORE TROUBLE SHOOTING YOUR FAN.
Trouble Shooting
TROUBLE | PROBABLE CAUSE |
| SUGGESTED REMEDY |
|
|
|
|
1. Fan will not | 1. Fuse or circuit breaker | 1. | Check main and branch |
start. | blown. |
| circuit fuses or circuit breakers. |
|
| ! | WARNING: Make sure |
|
|
| main power is turned off. |
| 2. Loose power line | 2. | Check line power connections |
| connections to the fan. |
| to fan. |
| 3. Fan/Light Wall Control is OFF. | 3. | Turn ON Fan/Light Wall Control. |
|
|
|
|
2. Fan sounds | 1. Blades not attached to fan. | 1. | Attach blades to fan before |
noisy. |
|
| operating. |
| 2. Screws securing fan blades | 2. | Check to make sure the screws |
| to motor are loose. |
| which attach the blades to the |
|
|
| motor are tight. |
|
| ! | WARNING: Make sure main |
|
|
| power is turned off. |
| 3. Loose screws in motor housing. | 3. | Check to make sure all screws |
|
|
| in motor housing are snug |
|
|
| (not |
|
|
|
|
3. Fan wobbles | 1. Setscrew in the hanger ball/ | 1. | Tighten the setscrew in the |
excessively. | downrod assembly is loose. |
| hanger ball/downrod assembly. |
| 2. Screws securing fan blades | 2. | Check to be sure screws which |
| to motor are loose. |
| attach the fan blade to the |
|
|
| motor are tight. |
| 3. Fan blades are not seated | 3. | Check to be sure that the |
| properly. |
| screws securing the fan |
|
|
| blades seat firmly. |
| 4. Hanger bracket and/or ceiling | 4. | Tighten the hanger bracket |
| outlet box is not securely |
| screws to the outlet box, and/or |
| fastened. |
| secure outlet box. |
| 5. Fan blades out of balance. | 5. | Interchanging an adjacent (side |
|
|
| |
|
|
| redistribute the weight and result |
|
|
| in smoother operation. |
|
|
|
|
14 | Model No.: CF3600 |