1.Remove the hanger ball by loosening the setscrew in the hanger ball until the ball falls freely down the downrod (Figure 1). Remove the pin from the downrod, then remove the hanger ball. Retain the pin and hanger ball for reinstallation in step 5.

PIN

HANGER

BALL

DOWNROD

SETSCREW

Figure 1

2.Unscrew the setscrew (Figure 2) until it clears the inside of the motor coupling. Then separate, untwist and unkink the three 80” motor leads. Route the motor lead wires through the downrod. Align the clevis pin holes in the downrod with the holes in the motor coupling. Install the clevis pin and secure with the hairpin clip (Figure 2). The clevis pin must go through the holes in the motor coupling and the holes in the downrod. Be sure to push the straight leg of the hairpin clip through the hole near the end of the clevis pin until the curved portion of the hairpin clip snaps around the clevis pin. The hairpin clip must be properly installed to prevent the clevis pin from working loose. Pull on the downrod to make sure the clevis pin is properly installed.

!WARNING

It is critical that the clevis pin in the motor coupling is properly installed and the setscrew securely tight- ened. Failure to verify that the pin and setscrew are properly installed (as shown in Figure 2) could result in the fan falling.

MOTOR

COUPLING

HAIRPIN

SETSCREW

CLEVIS PIN

CLIP

 

4.Place the ceiling cover over the downrod, making sure that the large opening faces upward (Figure 3).

HANGER

PIN

BALL

 

SETSCREW Manual background

DOWNROD

Manual background CEILING COVER

Figure 3

5.Reinstall the hanger ball (Figure 3) on the downrod as follows. Route the three 80” motor leads through the hanger ball. Position the pin through the two holes in the downrod and align the hanger ball so the pin is captured in the groove in the top of the hanger ball. Pull the hanger ball up tight against the pin and securely tighten the setscrew in the hanger ball. A loose setscrew could create fan wobble.

!WARNING

It is critical that the pin in the hanger ball is properly installed and the setscrew securely tightened. Failure to verify that the pin and setscrew are proper- ly installed could result in the fan falling.

6.The fan comes with blue, black and white leads that are 80-inches long. Before installing the fan, measure up approximately 6 to 9-inches above top of hanger ball/downrod assembly. Cut off excess leads and strip back insulation 1/2-inch from end of leads.

7.Mount blade flanges to fan blades using three 3/16-24 x 5/16” slotted Phillips head screws and three blade washers (Figure 4).

!WARNING

To reduce the risk of personal injury, do not bend the blade flange when installing the blade flanges, balancing the blades or cleaning the fan. Do not insert foreign objects in between rotating fan blades.

HAIRPIN CLIP

DOWNROD

CLEVIS

PIN

3/16-24 x 5/16" SLOTTED Manual backgroundManual background

PHILLIPS HEAD SCREW (3)

BLADE WASHER (3) Manual background

MOTOR COUPLING

Manual background SETSCREW

Figure 2

3.Tighten the setscrew (Figure 2) securely while pulling up on the downrod.

NOTE: The setscrew must be properly installed as described above, or fan wobble could result.

4

FAN BLADE Manual background

BLADE FLANGE

Figure 4

8.Turn the fan assembly upside down in preparation for mounting the fan blade assemblies. Remove and discard three shipping retainers securing the motor hub in the motor housing.

Page 4