BP7309 BANFF 1/5/06 9:59 AM Page 11
9. Position the downlight fitter assembly on the light fitter adapter plate so that the two screws and lockwashers mate with the keyhole slots in the downlight fitter assembly. Make sure that all wires and wire connectors are positioned within the downlight fitter assembly. Rotate the downlight fitter assembly clockwise and tighten the two screws. Install the other M4 x 8mm oval head screw and lockwasher in the remaining hole in the downlight fitter assembly.
! WARNING
Make sure there are no wires pinched between the light fitter and the fitter adapter plate.
Operating Your
Ceiling Fan
IMPORTANT
Fan installation must be completed, including the installation of the fan blades, before testing of the remote control.
Your Fan/Light Wall Control (Figure 15) has full control of your fan and lights. However, airflow direction is controlled by a slide switch on the switch housing.
1.Restore electrical power to the outlet box by turning the electricity on at the service panel.
NOTE: Make sure that the ON/OFF slide switch on the Fan/Light Wall Control is in the ON position.
DOWNLIGHT FITTER ASSEMBLY
TAB
FLAT
AREA
Figure 14
INSTALL THREE M4 x 8mm OVAL HEAD SCREWS AND LOCKWASHERS
CANDELABRA BULB (2)
LOWER
GLASS
BOWL
2. To set the desired fan speed, press the HI, MED, or LOW buttons to operate your fan on high, medium, or low speed (Figure 15).
3. To turn your fan off, press the OFF button.
4. To set the level of light brightness, press and hold the LIGHT button. The light brightness will continue to increase then decrease while the button is held down. When the lights are at the desired brightness, release the button.
5. To turn the lights on and off, press and
10. Screw in two
11. Place the lower glass bowl into the downlight fitter, aligning the three flat areas on the glass bowl flange with the three tabs on the downlight fitter (Figure 14). Then turn the lower glass bowl clockwise until the glass bowl stops turning.
12. Your ceiling fan is now installed and wired to be controlled by your SW101 Fan/Light Wall Control.
release the LIGHT button. The lights will turn on at the light level previously set (see step 4).
6. If airflow is desired in the opposite direction, turn the fan off and wait for the blades to stop turning. Then slide the reversing switch (on the motor and housing uplight assembly) to the opposite position (Figure 16) and turn the fan on again. The blades will turn in the opposite direction and reverse the airflow.
11