How to Wire Your Ceiling Fan - Dual Slide Wall Control
NOTE: Installation of this control requires that a
! WARNING
Turning off wall switch is not sufficient. To avoid possible electrical shock, be sure electricity is turned off at the main fuse or circuit breaker box before wiring. All wiring must be in accordance with National and Local codes and the ceiling fan must be properly grounded as a precaution against possible electrical shock.
! WARNING
To avoid possible fire or shock, follow all wiring instructions carefully. Any Electrical work not described in these instructions should be done or approved by a licensed electrician.
! WARNING
To avoid possible electrical shock, be sure electricity is turned off at the main fuse or circuit breaker panel. NOTE: If you are not sure if the outlet box is grounded, contact a licensed electrician for advise, as it must be grounded for safe operation.
1.Remove the wall plate and screws from the existing wall switch. Pull switch out from wall outlet box.
2. Disconnect wire from existing fan wall switch (Figure 19).
WALL OUTLET BOX
•Blue and yellow wires from fan to blue wire from fan/light control.
•Black/white wire from fan/light control to black wire from the 120V AC supply source.
| BLUE LIGHT SWITCH LEAD |
YELLOW LIGHT | TO HOT |
SWITCH LEAD | BLACK/WHITE |
4 3 2 1
EMERSON
LIGHT | BACK VIEW | |
SWITCH | ||
| ||
SPEED | BLACK SPEED CONTROL LEAD | |
SWITCH |
Figure 20
! WARNING
Check to see that all connections are tight, including ground, and that no bare wire is visible at the wire connectors, except for the ground wire. Do not operate fan until blades are in place. Noise and fan damage could result.
5.Attach the fan/light control to the outlet (wall) box using two
6.Installation of the ceiling fan is now complete. Restore power at the main fuse box or circuit breaker panel.
OUTLET BOX
DUAL SLIDE
WALL CONTROL
SWITCH
Figure 19 | WALL PLATE |
3.Set all knobs on the fan/light control in the off (down) position (Figure 20).
4.Make the following wire connections (Figure 20)
and secure with wire connectors supplied: | Figure 21 |
•Black wire from fan to black wire from fan/light control.
•White wire from fan to white wire from the 120V AC supply source.
4 3 2 1
EMERSON
WALL PLATE
10 | U.L. Model No.: CF830 |