6.Screw in four 40-watt (maximum) candelabra base lamps in the housing sockets (Figure 6). Grasp the sockets and pivot them until the lamp bulbs are even with the outer edge of the housing as shown. This will provide the optimum lighting effect.

PIN

HANGER

BALL Manual background SETSCREWManual backgroundManual background

DOWNROD

Manual background CEILING COVER

CEILING

AT LEAST

7'

Figure 5

Figure 7

FLOOR

5.Reinstall the hanger ball (Figure 5) on the downrod as follows. Route the two 80” motor leads through the hanger ball. Position the pin through the two holes in the downrod and align the hanger ball so the pin is captured in the groove in the top of the hanger ball. Pull the hanger ball up tight against the pin. Securely tighten the setscrew in the hanger ball. A loose setscrew could create fan wobble.

!WARNING

It is critical that the pin in the hanger ball is properly installed and the setscrew securely tightened. Failure to verify that the pin and setscrew are proper- ly installed could result in the fan falling.

6.Screw in four 40-watt (maximum) candelabra base lamps in the housing sockets (Figure 6). Grasp the sockets and pivot them until the lamp bulbs are even with the outer edge of the housing as shown. This will provide the optimum lighting effect.

!WARNING

The outlet box must be securely anchored and capable of withstanding a load of at least 50 lbs.

!WARNING

To reduce the risk of fire, electric shock, or personal injury, mount fan to outlet box marked acceptable for fan support, and use screws supplied with outlet box. Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced. Consult a qualified electrician in in doubt.

8.Securely attach the hanger bracket to the outlet box using the two screws supplied with the outlet box. (Figure 8.)

!WARNING

Hanger bracket must seat firmly against outlet box. If the outlet box is recessed, remove wall board until bracket contacts box. If bracket and/or outlet box are not securely attached, the fan could wobble or fall.

TOP ALIGN WITH

OUTER EDGE OF

THE HOUSING

SOCKET

 

Figure 6

CANDELABRA

BASE LAMP

7.The fan comes with black and white leads that are 80” long. Before installing fan, measure up approxi- mately 6 to 9-inches above top of hanger ball/down- rod assembly. Cut off excess leads and strip back insulation 1/2-inch from end of leads.

!WARNING

The fan must be hung with at least 7' of clearance from floor to blades (Figure 7).

6

 

OUTLET

 

BOX

TWO SCREWS

 

SUPPLIED WITH

HANGER

OUTLET BOX

 

BRACKET

Figure 8

TAB

 

9.Carefully lift the fan and seat the hanger ball/down- rod assembly on the hanger bracket that was just attached to the outlet box (Figure 9). Be sure the groove in the ball is lined up with tab on the hanger bracket (Figure 8).

!WARNING

Failure to seat tab in groove could cause damage to electrical wires and possible shock or fire hazard.

!WARNING

To avoid possible fire or shock, do not pinch wires between the hanger ball/downrod assembly and hanger bracket.