Emerson MSP422 manual Ptfe

Models: MSP422

1 40
Download 40 pages 63.63 Kb
Page 16
Image 16

Mobrey MSP422

Reference Manual

IP2013, Rev BA

February 2012

Figure 3-2.

Mounting The Mobrey MSP422

Using A Nozzle/Stand-off

Use Non-metallic

Fitting / Flange

Tighten To A Torque Of 1.5 lbf.ft (2 Nm) Using The Hexagon. Do Not Use The Housing To Tighten

PTFE

L

D

Table 3-1. Nozzle Diameter Size (D) and Max Length (L)

Figure 3-3.

Mounting the Mobrey MSP422

Using a Bracket Kit

NOTE:

If the transmitter face does not protrude into the vessel, note the dimensions in Table 3-1 for Figure 3-2, and always ensure that the nozzle/vessel weld is smooth and free from internal weld beads or other projections.

Nozzle Diameter Size (D)

Maximum Nozzle Length (L)

DN50 (2 in.)

4 in. (100 mm)

DN80 (3 in.)

6.3 in. (160 mm)

DN100 (4 in.)

6.3 in. (160 mm)

DN125 (5 in.)

11.8 in. (300 mm)

Stainless Steel Bracket

PVC Disc

No. 4X 13 Long Self Tap

Screw (3 Positions)

Carbon Steel (Zinc Plated)

Note: Combined weight of bracket and disc is 16 oz (0,5 kg)

3-6

Page 16
Image 16
Emerson MSP422 manual Ptfe