Environment

 

Ambient Temperature(2)

–4 to 158 °F (–20 to 70 °C)

Process Temperature

–4 to 158 °F (–20 to 70 °C)

Process Pressure

–4 to 44 psi (–0,25 to 3,0 bar)

Ingress Protection

IP 66

Electromagnetic Compatibility

EN61326 (Class B)

Certifications

CE-mark

(1)Temperature: 68 °F (20 °C), Pressure: 1013 mbar (atmospheric pressure), and Relative Humidity: 50%.

(2)See page A-2 onwards for approval temperature ranges.

TEMPERATURE AND PRESSURE RATINGS

Figure A-1.

The process temperature/pressure rating depends on the design of the transmitter in combination with the flange materials.

Process Temperature and Pressure Diagram

Pressure psi (bar)

44psi (3 bar)

OPERATING RANGE

The final rating may be limited by flange selection

-4 psi (-0,25 bar)

-4 °F (-20 °C)

158

°F

 

(70

°C)

Temperature °F (°C)

LOAD LIMITATIONS

Figure A-2. Load Limitations

The maximum load resistance can be determined from Figure A-2.

R (Ohms)

 

 

 

1244

 

 

 

800

 

 

 

533

 

 

 

400

 

 

 

0

 

 

U (V)

0

12

20

24

30

NOTE

R = Maximum Load Resistance

U = External Power Supply Voltage