SERVICING

The only maintenance required is to occasionally check the transmitter face to

 

ensure it remains clean and check that the cover seal, wiring, and cable

 

glands are in good condition.

 

There are no spare parts for the Mobrey MSP422. If a problem persists,

 

contact Mobrey Measurement for advice.

DIAGNOSTICS FOR THE MSP422

General Troubleshooting

Error Messages

No Display

Check the power supply. Ensure there is a minimum of 12 Vdc at the instrument terminals. Check that the cable insulation is not preventing contact at the terminal block.

No Level Reading

Check that the instrument is ticking about once per second. If there is no ticking, the instrument should be replaced.

Flashing “LE” With “0000”

The transmitter is not receiving a return echo, which could mean the liquid surface is poor or that it is beyond the range of 26 ft. (8 m) of the instrument. Change the position of the transmitter or contact Mobrey Measurement for information on longer range instruments

This means that the transmitter is not receiving a return echo, possibly because the liquid surface is poor or beyond the range (26 ft./8 m) of the instrument. Re-locate the instrument or contact Mobrey Measurement for details of longer range instruments.

Flashing “LE” With Level Reading

This means that the transmitter is no longer receiving satisfactory echoes from the liquid surface. This may be because of one of a variety of reasons, for example, excessive foaming, turbulence, or ullage vapors.

First, check that the transmitter face is free from contamination and condensation. The transmitter will operate with some condensation on the face, but excessive condensation may cause operational problems. If the vessel cannot be adequately vented to prevent condensation forming, contact Mobrey Measurement for alternative solutions.

Second, check that the instrument is still vertically aligned above the liquid surface and check the echo received size. If the echo size is small (<3), re-position the transmitter or modify the vessel for the transmitter to operate above a more acceptable area of the liquid surface.

Lost echo (LE) is signalled when there has been no return echo for 10 seconds. Within the 10 seconds, the output will remain fixed. If, after the 10 seconds, no satisfactory has been received, the output will increase to the current selected level and the display flashes alternately “LE” and the last valid level reading.

If a satisfactory echo is received within the 10 seconds, a new output is established and the LE timer is re-set.

5-2

Page 32
Image 32
Emerson manual Servicing, Diagnostics for the MSP422, General Troubleshooting Error Messages

MSP422 specifications

The Emerson MSP422 is an advanced multi-sensor platform designed for various industrial applications, providing crucial data insights for efficient operations. This innovative device integrates multiple measurement technologies, including temperature, pressure, and humidity sensors, into a single unit, making it an ideal choice for monitoring diverse environments and processes.

One of the key features of the MSP422 is its robust design, tailored for industrial applications. The unit is built to withstand harsh conditions, including extreme temperatures and moisture levels, ensuring reliable performance even in challenging environments. Its durability makes it suitable for industries such as oil and gas, chemical processing, and pharmaceuticals.

The MSP422 stands out with its high precision and accuracy across all its sensor capabilities. The temperature sensor operates within a wide range, offering precise readings essential for maintaining optimal operational conditions. Similarly, the pressure measurements are finely tuned, providing critical insights for process control and safety monitoring.

Connectivity is another major advantage of the MSP422. Equipped with advanced communication protocols, it facilitates seamless integration with existing industrial systems. Users can easily connect the MSP422 to their industrial automation systems, enabling real-time data transmission and allowing for timely decision-making. The device supports protocols like Modbus, making it versatile for various applications.

The MSP422 is also designed with user-friendly interfaces, including customizable dashboards and data visualization tools. This feature enhances the user experience, allowing operators to easily monitor parameters and analyze data trends over time. The intuitive interface reduces the learning curve, enabling quick adaptation in dynamic industrial environments.

Power management is another critical characteristic of the MSP422. It is designed for low power consumption, which is essential for minimizing operational costs and extending the lifespan of the device. The platform can operate on various power sources, providing flexibility in deployment across diverse sites.

In summary, the Emerson MSP422 is a leading multi-sensor platform that brings together precision measurement, rugged design, connectivity, user-friendly interfaces, and efficient power management. Its versatile features make it an essential asset for industries seeking to enhance monitoring, improve efficiency, and maintain safety in their operations.