Rockford Fosgate RFX8220, RFX8230, RFX8210 manual IR Remote Troubleshooting, No CD

Models: RFX8210 RFX8220 RFX8230

1 37
Download 37 pages 30.3 Kb
Page 35
Image 35

SYMPTOM

DIAGNOSIS

REMEDY

Error 7

The laser pick-up is

Repair the laser pick-up

(Focus Error)

defective

 

 

 

 

 

Disc is warped,

Put in a new disc

 

cracked or damaged

 

 

 

 

Error 9

Disc is warped,

Eject damaged disc from source

(TOC Error)

cracked or severely

unit and play only non-damaged

 

damaged.

discs

 

 

 

 

The laser pick-up is

Have a service center repair the

 

defective

laser pick-up

 

 

 

NO CD

Magazine is empty or

Check the magazine and insert

(No Disc Error)

not installed in the unit

discs

 

 

 

NO CONN

8-pin DIN cable is

Check the connection of 8-pin

(Communication Error)

disconnected from the

DIN cable between the CDX

 

CDX mechanism or

and unit

 

source unit

 

 

 

 

SYMPTOM

DIAGNOSIS

REMEDY

CD Changer does

CDX cable is inter-

Check connections and repair or

not operate

mittent or severely

replace CDX cable as necessary

 

damaged

 

 

 

 

 

CDX cable is discon-

Check connections at the Source

 

nected from the Source

unit and CD Changer and repair

 

Unit or CD Changer

wiring as necessary

 

 

 

 

Communication

Press “Reset” button on CD

 

problem

Changer

 

 

 

Disc is jammed in

Disc load/unload

Press “Reset” button on CD

the CD Changer

problem

Changer. If CD Changer still

 

 

does not operate, see your Local

 

 

Authorized Rockford Fosgate

 

 

Dealer

 

 

 

IR REMOTE TROUBLESHOOTING

SYMPTOM

DIAGNOSIS

REMEDY

IR Remote has

Batteries are weak

Check battery condition and

poor range

 

replace as necessary with

 

 

(1) CR2025 (+3 volt) battery

 

 

 

 

Excessive dirt or dust

Clean transmitter lens with

 

on IR Remote trans-

Plexiglas solution and a non-

 

mitter lens

abrasive cloth as necessary

 

 

 

 

Excessive dirt or dust

Clean receiver lens (compact disc

 

on source unit receiver

logo) with Plexiglas solution and a

 

lens

non-abrasive cloth as necessary

 

 

 

 

IR remote is outside of

Operate IR remote within approx-

 

optimum transmitting

imately 15 ft and ±45˚ from

 

range

horizontal of the Source unit’s

 

 

faceplate

 

 

 

 

High sunlight

Operate IR remote closer to

 

conditions

Source Unit

 

 

 

IR Remote does

Batteries are dead

Check battery condition and

not work

 

replace as necessary with

(LED does not

 

(1) CR2025 (+3 volt) battery

illuminate)

 

 

Battery is installed

Check battery installation and

 

 

incorrectly

repair as necessary (polarity is

 

 

indicated on pc board)

 

 

 

– 66 –

– 67 –

Page 35
Image 35
Rockford Fosgate RFX8220, RFX8230, RFX8210 manual IR Remote Troubleshooting, No CD