Specifications and Dimensions

Specifications

 

Environment

 

Ambient Operating

32 to 104 °F (0 to 40 °C)

Temperature

32 to 122 °F (0 to 50 °C) with derating

Cooling method

Forced convection

Humidity

95% maximum non-condensing at 104 °F

 

(40 °C)

Storage Temperature

-40 to 122 °F (-40 to 50 °C)

Altitude

0 to 9,900ft (0 to 3000m). Derate 1% per 328ft

 

(100m) between 3280ft (1000m) and 9,900ft

 

(3000m)

Vibration

Tested in accordance with IEC 60068-2-6,

 

2-29, 2-64

Mechanical Shock

In accordance with IEC 60068-2-27

Enclosure

NEMA 1 (IP 20), NEMA 12 (IP 54) through-panel

 

mounting

Electromagnetic

In compliance with EN 61800-3 and

Immunity

EN 61000-6-2, and complies with

 

EN61800-3 2nd environment with built-in filter

Electromagnetic

In compliance with EN61000-6-4 when the

Emissions

recommended RFI filter is used and EMC

 

installation guidelines are followed

AC Supply

 

Requirements

 

Voltage

200 to 240Vac ±10%

 

380 to 480Vac ±10%

 

500 to 575Vac ±10%

 

500 to 690Vac ±10%

Phase

3Ø (SP size Zero: 200 to 240V 1Ø or 3Ø)

Phase Imbalance

2% negative phase sequence (equivalent to 3%

 

voltage imbalance between phases)

Frequency

48 to 65Hz

Input Power Factor

Displacement 0.97

Control

 

Carrier Frequency

3, 4, 6, 8, 12,16kHz - Panel Mount drives

 

3, 4, 6kHz - Free Standing and SPM drives

Output Frequency

0 to 3000Hz (Open-loop)

Output Speed

0 to 40,000rpm (Closed-loop)

Frequency Accuracy

±0.01% of full scale

Frequency Resolution

0.001Hz

Analog Input

10 bit + sign (Qty 2); 16 bit + sign (Qty 1)

 

resolution

Serial

2-wire RS485

Communications

4-wire RS232 or RS485 with SM-APPS module

 

Protocol is ANSI x 3.28-2.5-A4, or Modbus RTU

 

Baud rate 300 to 115,200

Braking

DC injection braking (stopping and holding) and

 

dynamic braking transistor standard.

Control Power Ride

Up to 1 second depending on inertia and decel

Through

time

Protection

 

DC Bus

175 / 330 / 435Vdc (approximately

Undervoltage Trip

124 / 233 / 307Vac line voltage)

DC Bus

415 / 830 / 990Vdc (approximately 293 / 587 /

Overvoltage Trip

700Vac line voltage)

MOV Voltage

120 Joules, 1500Vdc clamping (line-to-line);

Transient Protection

140 Joules, 1815Vdc clamping (line-to-ground)

Drive Overload Trip

Current overload value is exceeded

 

Programmable for Normal Duty or Heavy Duty,

 

open-loop or closed-loop operation

Instantaneous

225% of drive rated current

Overcurrent Trip

 

Phase Loss Trip

DC bus ripple threshold exceeded

Overtemperature

Drive heatsink, control board, and option

Trips

module(s) monitoring

Short Circuit Trip

Protects against output phase to phase fault

Ground Fault Trip

Protects against output phase to ground fault

Motor Thermal Trip

Electronically protects the motor from

 

overheating due to loading conditions

Dimensions

SP Control

 

 

Platform

4.4in

Weight 3.3lbs

(112mm)

 

 

 

17.6in

 

 

 

 

 

(448mm)

 

 

 

 

6.4in

 

(162mm)

Size SP2

 

 

Weight 15.5lbs

 

6.1in

 

 

 

(155mm)

Size SP0

Weight 4.6lbs

8.9in

 

 

(226mm)

 

12.7in

 

(322mm)

9.8in

(249.7mm)

 

2.4in

 

(62mm)

Size SP3

Weight 33lbs

9.8in

 

 

(250mm)

Size SP1

 

Weight 11lbs

3.9in

 

(100mm)

 

14.5in

 

(368mm)

 

8.6in

 

(219mm)

Size SP4

 

Weight 66lbs

12.2in

 

 

(310mm)

Size SP6

Weight 165.3lbs

12.2in (310mm)

Size SP5

Weight 121lbs

12.2in (310mm)

44.5in (1131mm)

32.3in (820mm)

14.5in

14.5in

(368mm)

 

(368mm)

8.6in

10.2in

(219mm)

(260mm)

 

20.1in (510mm)

11.7in (298mm)

11.7in

11.7in

(298mm)

(298mm)

18

www.controltechniques.com