Emerson E171230, N1652 manual Ratings, Frame Size

Models: N1652 E171230

1 20
Download 20 pages 52.17 Kb
Page 19
Image 19

Ratings

SizeFrame

0

200-240Vac

Normal Duty

 

+/- 10% 3Ø

 

 

 

(kW@220V,

Max

Motor

Typical

hp@230V)

Continuous

Power

Output

Order Code

Current (A)

(hp)

(kW)

 

 

 

SP0201

2.2

0.5

0.37

 

 

 

 

SP0202

3.1

0.75

0.55

 

 

 

 

SP0203

4

1

0.75

 

 

 

 

SP0204

5.7

1.5

1.1

 

 

 

 

SP0205

7.5

2

1.5

SP1201

5.2

1.5

1.1

Heavy Duty

Max

Motor

Typical

Continuous

Power

Output

Current (A)

(hp)

(kW)

 

 

 

2.2

0.5

0.37

 

 

 

3.1

0.75

0.55

 

 

 

4

1

0.75

 

 

 

5.7

1.5

1.1

 

 

 

7.5

2

1.5

4.3

1

0.75

SizeFrame

0

 

200-240Vac

Normal Duty

 

 

 

+/- 10% 1Ø

 

 

 

 

 

 

(kw@220V,

Max

Motor

 

Typical

 

hp@230V)

Continuous

Power

 

Output

 

Order Code

Current (A)

(hp)

 

(kW)

 

 

 

 

 

 

 

SP0201

 

0.5

 

0.37

 

 

2.2

 

 

 

SP0202

3.1

0.75

 

0.55

 

 

SP0203

4

1

 

0.75

 

 

SP0204

5.7

1.5

 

1.1

 

 

SP0205

7.5

2

 

1.5

 

 

 

 

 

 

 

 

Heavy Duty

Max

Motor

Typical

Continuous

Power

Output

Current (A)

(hp)

(kW)

 

 

 

2.2

0.5

0.37

3.1

0.75

0.55

4

1

0.75

5.7

1.5

1.1

7.5

2

1.5

 

 

 

1

2

3

4

5

SizeFrame

SP1202

6.8

2

1.5

SP1203

9.6

3

2.2

 

 

 

 

SP1204

11

3

3

SP2201

15.5

5

4

 

 

 

 

SP2202

22

7.5

5.5

 

 

 

 

SP2203

28

10

7.5

SP3201

42

15

11

 

 

 

 

SP3202

54

20

15

SP4201

68

25

18.5

 

 

 

 

SP4202

80

30

22

 

 

 

 

SP4203

104

40

30

SP5201

130

50

37

 

 

 

 

SP5202

154

60

45

380-480Vac

Normal Duty

 

 

 

 

+/- 10% 3Ø

 

 

 

(kW@400V,

Max

Motor

Typical

hp@460V)

Continuous

Power

Output

Order Code

Current (A)

(hp)

(kW)

 

 

 

SP0401

1.3

0.5

0.37

 

 

 

 

SP0402

1.7

0.75

0.55

5.8

1.5

1.1

7.5

2

1.5

 

 

 

10.6

3

2.2

 

 

 

12.6

3

3

 

 

 

17

5

4

 

 

 

25

7.5

5.5

 

 

 

31

10

7.5

 

 

 

42

15

11

 

 

 

56

20

15

 

 

 

68

25

18.5

 

 

 

80

30

20

 

 

 

105

40

30

 

 

 

130

50

37

 

 

 

 

Heavy Duty

 

Max

Motor

Typical

Continuous

Power

Output

Current (A)

(hp)

(kW)

 

 

 

1.3

0.5

0.37

 

 

 

1.7

0.75

0.55

Frame Size

3

4

5

6

 

500-575Vac

Normal Duty

 

 

 

+/- 10% 3Ø

 

 

 

 

 

 

(kW@575V,

Max

Motor

 

Typical

 

hp@575V)

Continuous

Power

 

Output

 

Order Code

Current (A)

(hp)

 

(kW)

 

 

 

 

 

 

 

SP3501

 

3

 

3

 

 

5.4

 

 

 

SP3502

6.1

5

 

4

 

 

SP3503

8.4

7.5

 

5.5

 

 

 

 

 

 

 

 

 

SP3504

11

10

 

7.5

 

 

 

 

 

 

 

 

 

SP3505

16

15

 

11

 

 

 

 

 

 

 

 

 

SP3506

22

20

 

15

 

 

 

 

 

 

 

 

 

SP3507

27

25

 

18.5

 

 

SP4603*

36

30

 

22

 

 

 

 

 

 

 

 

 

SP4604*

43

40

 

30

 

 

 

 

 

 

 

 

 

SP4605*

52

50

 

37

 

 

 

 

 

 

 

 

 

SP4606*

62

60

 

45

 

 

SP5601*

84

75

 

55

 

 

 

 

 

 

 

 

 

SP5602*

99

100

 

75

 

 

SP6601*

125

125

 

90

 

 

 

 

 

 

 

 

 

SP6602

144

150

 

110

 

 

 

 

 

 

 

 

Heavy Duty

Max

 

Motor

Typical

Continuous

 

Power

Output

Current (A)

 

(hp)

(kW)

4.1

 

2

 

 

2.2

5.4

 

3

3

6.1

 

5

4

9.5

 

7.5

5.5

12

 

10

7.5

18

 

15

11

22

 

20

15

27

 

25

18.5

36

 

30

22

43

 

40

30

52

 

50

37

63

 

60

45

85

 

75

55

100

 

100

75

125

 

125

90

 

 

 

 

0

1

2

3

SP0403

2.1

1

0.75

 

 

 

 

SP0404

3

1.5

1.1

 

 

 

 

SP0405

4.2

2

1.5

SP1401

2.8

1.5

1.1

 

 

 

 

SP1402

3.8

2

1.5

 

 

 

 

SP1403

5

3

2.2

 

 

 

 

SP1404

6.9

5

3

 

 

 

 

SP1405

8.8

5

4

 

 

 

 

SP1406

11

7.5

5.5

SP2401

15.3

10

7.5

SP2402

21

15

11

SP2403

29

20

15

SP2404

29

20

15

SP3401

35

25

18.5

 

 

 

 

SP3402

43

30

22

2.1

1

0.75

 

 

 

3

1.5

1.1

 

 

 

4.2

2

1.5

 

 

 

2.1

1

0.75

 

 

 

3

1.5

1.1

 

 

 

4.2

2

1.5

 

 

 

5.8

3

2.2

 

 

 

7.6

5

3

 

 

 

9.5

5

4

13

7.5

5.5

16.5

10

7.5

25

15

11

29

20

15

 

 

 

32

25

15

 

 

 

40

30

18.5

SizeFrame

4

5

6

 

500-690Vac

Normal Duty

 

 

 

+/- 10% 3Ø

 

 

 

 

 

 

(kW@690V,

Max

Motor

 

Typical

 

hp@690V)

Continuous

Power

 

Output

 

Order Code

Current (A)

(hp)

 

(kW)

 

 

 

 

 

 

 

SP4601

 

25

 

18.5

 

 

22

 

 

 

 

 

 

 

 

 

 

SP4602

27

30

 

22

 

 

 

 

 

 

 

 

 

SP4603

36

40

 

30

 

 

 

 

 

 

 

 

 

SP4604

43

50

 

37

 

 

 

 

 

 

 

 

 

SP4605

52

60

 

45

 

 

 

 

 

 

 

 

 

SP4606

62

75

 

55

 

 

SP5601

84

100

 

75

 

 

SP5602

99

125

 

90

 

 

SP6601

125

150

 

110

 

 

SP6602

144

175

 

132

 

 

 

 

 

 

 

 

Heavy Duty

Max

Motor

Typical

Continuous

Power

Output

Current (A)

(hp)

(kW)

 

 

 

19

20

15

 

 

 

22

25

18.5

 

 

 

27

30

22

 

 

 

36

40

30

 

 

 

43

50

37

 

 

 

52

60

45

63

75

55

85

100

75

100

125

90

125

150

110

 

 

 

4

5

6

SP3403

56

40

30

SP4401

68

50

37

 

 

 

 

SP4402

83

60

45

 

 

 

 

SP4403

104

75

55

SP5401

138

100

75

 

 

 

 

SP5402

168

125

90

SP6401

205

150

110

 

 

 

 

SP6402

236

200

132

46

30

22

 

 

 

60

40

30

 

 

 

74

50

37

 

 

 

96

75

45

 

 

 

124

100

55

 

 

 

156

125

75

 

 

 

180

150

90

 

 

 

210

150

110

Notes:

Select model on actual motor full load current. *The same model can be used on a

 

575V or a 690V supply, and has two different output ratings. For example: At Normal

 

Duty, SP4603 is suitable for a 30hp output motor on a 575V supply and a 40hp output

 

motor on a 690V supply. Can be used on IT supplies - all voltages, Grounded delta

 

supplies - all voltages except 690V

 

 

 

 

Normal Duty

 

Heavy Duty

 

Suitable for most

 

Suitable for demanding applications, current overload of 175%

 

applications, current

 

for 40 seconds is available for frame size 0 - 5 in closed-loop,

 

overload of 110% for 165

 

150% for 60 seconds in open-loop, and size 0 single phase

 

seconds is available. Where

 

current overload is 150% for 60 seconds. For frame size 6 current

 

motor rated current is

 

overload of 150% for 60 seconds is available in closed-loop

 

less than the drive rated

 

and 129% for 97 seconds in open-loop. Where the motor rated

 

continuous current, higher

 

current is less than the drive rated continuous current higher

 

overloads are achieved.

 

overloads (200% or greater) are achieved.

 

 

 

 

 

 

www.controltechniques.com

19

Page 19
Image 19
Emerson E171230, N1652 manual Ratings, Frame Size