ELITE-sensors (BVS 06 ATEX E 045 X)

Type

Classificatie

 

 

 

 

CMFHC3*****(2–9, A, B, D, E, Q,

0575

II 2 G Ex ib IIB T1–T5

–40°C Ta +55°C

V, W of Y)*Z****

 

II 2 D Ex tD A21

IP65 T1 °C

 

CMFHC3*****(2–9, A, B, D, E, Q,

0575

II 2 G Ex ib IIC T1–T5

–40°C Ta +55°C

V, W of Y)*Z**** CIC A4 (IIC)

 

II 2 D Ex tD A21

IP65 T1 °C

 

CMFHC3 (A, B, C of E)****(2–9,

0575

II 2

G Ex ib IIB T1–T5

–50°C Ta +55°C

A, B, D, E, Q, V, W of Y)*Z****

 

II 2

D Ex tD A21

IP65 T1 °C

Min. temp. voor stof is

 

 

 

 

 

–40°C

CMFHC3(A, B, C of E)****(2–9,

0575

II 2

G Ex ib IIC T1–T5

–50°C Ta +55°C

A, B, D, E, Q, V, W of Y)*Z****

 

II 2

D Ex tD A21

IP65 T1 °C

Min. temp. voor stof is

CIC A4 (IIC)

 

 

 

 

–40°C

(1) Zie de temperatuurgrafieken voor de stoftemperatuurwaarden.

5)Speciale voorwaarden voor veilig gebruik/installatie-instructies

5.1) Rechtstreekse montage van de sensor CMF********C*Z**** of CMF********F*Z**** aan de transmitter *700********* heeft gevolgen voor het gebruik van het instrument. Zie hiervoor de onderstaande tabel:

 

CMF010*****(C of F)*Z****

CMF200*****(C of F)*Z****

 

CMF025*****(C of F)*Z****

CMF300*****(C of F)*Z****

 

CMF050*****(C of F)*Z****

CMF400*****(C of F)*Z****

 

CMF100*****(C of F)*Z****

CMF200(A, B, C of E)****(C of F)*Z****

 

CMF100*****(C of F)*Z**** CIC: A4

CMF200(A, B, C of E)****(C of F)*Z****

Sensor

CMF200*****(C of F)*Z**** CIC: A4

CIC A5

 

CMF300*****(C of F)*Z**** CIC: A4

CMF300(A, B, C of E)****(C of F)*Z****

 

 

CMF400*****(C of F)*Z**** CIC: A4

CMF300(A, B, C of E)****(C of F)*Z****

 

 

 

CIC A5

 

 

 

 

CMF400(A, B, C of E)****(C of F)*Z****

 

 

 

CMF400(A, B, C of E)****(C of F)*Z****

 

 

 

CIC A5

 

 

 

 

 

 

Transmittertype

0575

II 2 G Ex ib IIB+H2 T1–T5

0575

II 2 G Ex ib IIB T1–T5

*700*1(1 of 2)*******

 

 

II 2 D Ex tD A21 IP65 T1 °C

 

II 2 D Ex tD A21 IP65 T1 °C

Transmittertype

0575

II 2 G Ex ib IIC T1–T5

0575

II 2 G Ex ib IIB T1–T5

*700*1(3, 4 of 5)*******

 

 

 

 

 

 

II 2 D Ex tD A21 IP65 T1 °C

 

II 2 D Ex tD A21 IP65 T1 °C

Transmittertype

0575

II 2 (1) G Ex ib IIB+H2 T1–5

0575

II 2 (1) G Ex ib IIB T1–5

*700*1(1 of 2)D******

 

 

II 2 D Ex tD A21 IP65 T1 °C

 

II 2 D Ex tD A21 IP65 T1 °C

Transmittertype

0575

II 2 (1) G Ex ib IIC T1–5

0575

II 2 (1) G Ex ib IIB T1–T5

*700*1(3, 4 of 5)D******

 

 

 

 

 

 

II 2 D Ex tD A21 IP65 T1 °C

 

II 2 D Ex tD A21 IP65 T1 °C

Transmittertype

0575

II 2 (1) G Ex ib IIB+H2 T1–5

0575

II 2 (1) G Ex ib IIB T1–T5

2700*1(1 of 2)(E of G)******

 

 

II 2 D Ex tD A21 IP65 T1 °C

 

II 2 D Ex tD A21 IP65 T1 °C

Transmittertype

0575

II 2 (1) G Ex ib IIC T1–5

0575

II 2 (1) G Ex ib IIB T1–T5

2700*1(3, 4 of 5)(E of G)******

 

 

 

 

 

 

II 2 D Ex tD A21 IP65 T1 °C

 

II 2 D Ex tD A21 IP65 T1 °C

(1) Zie de temperatuurgrafieken voor de stoftemperatuurwaarden.