If pilot flame pattern is incorrect, as shown in Figure 14
•See Troubleshooting, page 16.
Main Burner Flame Pattern (Figure 15 and Figure 16)
Figure 15 shows a correct main burner flame pattern. Figure 16 shows an incorrect main burner flame pattern.
Air Shutter Adjustment
An air shutter adjusting screw is located on the exterior, bottom of the inner body. Screw air shutter adjusting screw IN to close air shutter top (increase yellow flame). Screw air shutter adjusting screw OUT to open air shutter top (decrease yellow flame).
Correct Main Burner Flame
Figure 15
Incorrect Main Burner Flame
Figure 16
If main burner flame pattern is incorrect, as shown in Figure 16
•See Troubleshooting, page 16.
Cleaning and Maintenance / Main Burner Warning: Turn off heater and let cool before cleaning
After use, cleaning of the main burner may be required for the proper flame. The main burner may be cleaned by applying air pressure to the ports on the main burner.
Cleaning the Log Set and Firebox
During the annual inspection and maintenance appointment, the service person should clean dust, lint, and any light accumulation from the logs and the firebox area. An
CAUTION: The ceramic logs are durable when handled and installed properly. However, they are delicate and may be damaged easily if not handled with care. Handling damage to the ceramic logs is not covered by warranty.
DO NOT HANDLE LOGS WHILE THEY ARE HOT. ALLOW PLENTY OF TIME FOR THE APPLIANCE TO COOL COMPLETELY BEFORE HANDLING.
OPERATING INSTRUCTIONS
CIBV-30 ON/OFF/REMOTE Switch
Operation of ON/OFF/REMOTE Switch with no Accessories
To ignite main burner, turn the control knob on the gas valve from the PILOT position to the ON position. Turn the ON/OFF/REMOTE switch from the OFF position to the ON position. The additional green wire and red wire, which are stripped and bare are not used.
Operation of ON/OFF/REMOTE Switch with Accessories 750 Millivolt Wall Thermostat,
Connect the green and red, stripped and bare, wires on the ON/OFF/ REMOTE switch wire harness to the wall thermostat. Turn the ON/OFF/ REMOTE switch on the wiring chase to the REMOTE position. Set the wall thermostat to the desired temperature.
It is important to use wire of a gauge proper for the length of the wire:
RECOMMENDED WIRE GAUGES
Maximum | Wire |
Length | Gauge |
1' to 10' | 18 |
10' to 25' | 16 |
25' to 35' | 14 |
Wall Switch, FWS-1
Connect the green and red, stripped and bare, wires on the ON/OFF/ REMOTE switch wire harness to the wall switch. Turn the ON/OFF/ REMOTE switch on the wiring chase to the REMOTE position. Pivot the rocker switch on the
Battery Operated Remote Control,
Note: If batteries fail in