Empire Comfort Systems CIBV-30-2 OPTIONAL BLOWER CIB-2, Vented Fireplace Heater CIBV-30, Wiring

Models: CIBV-30-2

1 22
Download 22 pages 58.61 Kb
Page 20
Image 20
OPTIONAL BLOWER CIB-2

OPTIONAL BLOWER CIB-2

Vented Fireplace Heater CIBV-30

Installing Optional CIB-2 Blower

1.Loosen, but do not remove, (4) hex-head screws located on the exterior, bottom of the appliance.

2.Position the blower assembly at the rear of the appliance. The blower assembly has (4) keyholes for attachment to the exterior, bottom of the appliance.

3.Place the large diameter holes in the keyholes over and behind the (4) hex-head screws that were loosened in Step 1. Push inward on the blower assembly to lock the keyholes into position behind the screws. Tighten (4) hex-head screws to secure blower assembly to exterior, bottom of the appliance.

4.Remove wire channel from rear cover by removing (4) hex- head screws. Note: If optional blower is being installed during initial installation of appliance, the wire channel will not be attached to rear cover. (Refer to Installation of Wire Channel Assembly, Page 8)

5.Attach fan control to FLAT, fan control bracket (Part 9A, Page 21) with (2) 6 x 1/4" screws provided in hardware package.

6.Attach fan control with bracket onto the wire channel by using (2) 8 x 1/4" screws provided in hardware package.

7.Route wires from fan control and ON/OFF/REMOTE switch within wire channel.

8.When facing the rear of the appliance, align and insert fan control with bracket into 1 3/8" x 2" opening on the left side of the rear cover.

9.Attach wire channel to rear cover by using (4) hex-head screws removed in Step 4. (Refer to Installation of Wire Channel Assembly, Page 8)

10.Insert AUTO/OFF/ON switch into rectangular notch on valve bracket. Be sure to insert AUTO/OFF/ON switch with letters (words) upright. (See wiring diagram)

11.Attach 1/4" push-on terminal from blue wire on the fan control to the AUTO (top) tab on the switch.

12.Attach 1/4" push-on terminal from black wire to the OFF (middle) tab on the switch.

13.Attach 1/4" push-on terminal from white wire on the fan control to the ON (bottom) tab on the switch.

14.Installation of optional CIB-2 blower is completed.

Fan Control

The fan control is a non-adjustable automatic type. The fan control will require between 5 and 10 minutes of main burner operation before the fan control "closes" and activates the blower. The blower will continue to run between 5 and 10 minutes after the main burner shuts off, before the fan control "opens" and deactivates the blower.

Wiring

The appliance, when installed, must be electrically grounded in accordance with local codes or, in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70 or Canadian Electrical Code, CSA C22.1, if an external electrical source is utilized. This appliance is equipped with a three-prong [grounding] plug for your protection against shock hazard and should be plugged directly into a properly grounded three-prong receptacle. Do not cut or remove the grounding prong from this plug. For an ungrounded receptacle, an adapter, which has two prongs and a wire for grounding, can be purchased, plugged into the ungrounded receptacle and its wire connected to the receptacle mounting screws. With this wire completing the ground, the appliance cord plug can be plugged into the adapter and be electrically grounded.

CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing.

WARNING:

Unplugging of blower accessory will not stop the heater from cycling. To shut heater off: Turn temperature dial or thermostat to lowest setting. Turn knob on gas control to "OFF", depressing slightly. Do not force.