VENTING AND INSTALLATION

RECTANGULAR

TERMINATION CAP

(DVVK3FV KIT)

ROUND TERMINATION CAP

(DVKI KIT)

ROUND CO-LINEAR TO

CO-AXIAL ADAPTOR

VENT CLAMPS

RETAINER SCREWS MAY

BE INSTALLED THROUGH

THE VENT CLAMPS TO

ENSURE POSITIVE SECUREMENT

OF VENTING.

INTAKE VENT

FLUE EXHAUST VENT

VENT CLAMPS

OPTIONAL ON/OFF

SWITCH LOCATION

OPTIONAL

LOW VOLTAGE

WIRES

BLOWER

POWER CORD

Figure 8

NOTE: LONG EXTENSION

TUBE FOR INLET VENT

CONNECTION.

USE HIGH TEMP

SEALANT ON VENT

CONNECTIONS

10’ MINIMUM 35’ MAXIMUM

OPTIONAL ON/OFF

SWITCH LOCATION

USE HIGH TEMP

SEALANT ON VENT

CONNECTIONS

SCREWS ADDED THROUGH

VENT CLAMPS TO RETAIN

VENTING TO COLLARS

RECOMMENDED.

BLOWER ACCESS

COVER PLATE