FIREPLACE INSERT DIMENSIONS

When planning a fireplace insert installation, it’s necessary to determine:

The vent system configuration to be used.

Gas supply piping.

Whether optional accessories - devices such as a wall switch or remote control - are desired.

Electrical supply requirements for blower.

Proper opening size of fireplace required for installation of the fireplace insert.

DV FIREPLACE INSERT DIMENSIONS

MODEL

A

B

C

D

E

F

G

H

I

J

K

L

M

N

DV25IN

19 3/8”

28

14 1/2”

11 1/8”

25 1/4”

12 3/4”

17”

18 5/16”

27”

6 3/4”

9”

20”

25 3/8”

40”

DV33IN

22 3/8”

31

16

14 1/8”

28 1/4”

14 1/4”

18 3/4”

21 5/16”

30”

8 1/4”

10 1/2”

21 1/2”

28 3/8”

43”

DV35IN

24 3/8”

34

16

16 1/8”

31 1/4”

14 1/4”

21 3/4”

23 5/16”

33”

8 1/4”

10 1/2”

23”

30 3/8”

46”

Figure 1

Fireplace Opening Dimensional Information/Sizing

MINIMUM FIREPLACE OPENING DIMENSIONS

MODEL

HEIGHT

FRONT WIDTH

DEPTH

REAR WIDTH

NO.

A*

B

C

D

 

 

 

 

 

DV25IN

18 3/8”

27 1/2”

12 3/4”

17 1/4”

DV33IN

21 3/8”

30 1/2”

14 1/4”

19”

DV35IN

23 3/8”

33 1/2”

14 1/4”

22”

*Note: If the fireplace lintel is wider than 8” (203mm), the height of the fireplace opening must be increased a few inches to allow for a gradual offset in the exhaust and/or intake vent pipes.

D

C

A

B

Figure 2

23015-3-0707

Page 7

Page 7
Image 7
Empire Comfort Systems DV33IN33L, DV25IN33L, DV35IN33L installation instructions DV Fireplace Insert Dimensions