LOG SET INSTALLATION INSTRUCTIONS

Log Installation

All Logs

The gas log set (front left log, front right log, center log and rear

The positioning of the logs is critical to the safe and clean opera-

log) is pre-set and installed in the factory. Only the top left log and

tion of this heater. Sooting and other problems may result if the

top right log are packaged separately inside the firebox for instal-

logs are not properly and firmly positioned in the appliance.

lation by the installer.

6. Prior to positioning of top left log and top right log, inspect

1. To access the log set parcel, lift off top panel.

 

front burner and rear burner for particles or dust accumula-

2. Pivot left and right panels open.

 

tion on top of burners. If any particles or dust is visible on top

 

of front or rear burners, remove particles before placing top

3. Unlatch main door latches located on right and left hand side

 

 

left log and top right log into position.

of the heater, remove door.

 

7.

Position top left log into locating pin on rear log and rest on

4. Carefully remove top left log and top right log from firebox

 

center log. See Figure 15.

and remove cardboard protection from center log and middle

 

8.

Position top right log into locating slot on rear log. See Fig-

log and all packaging materials.

 

ure 15.

Note: Positions of front left log, front right log, center log,

 

9.

After top left log and top right log have been placed in posi-

and rear log have been preset at the factory and their loca-

 

tion and safety check has been carried out, install door and

tions should not be changed. Check that logs have not been

 

 

latch securely with latches located on right and left side of

damaged in transit.

 

 

heater.

5. Carefully remove wrapping from top left log and top right

 

 

 

log.

 

 

Note: Before you begin: Do not handle these logs with your bare

 

 

hands! Always wear gloves to prevent skin irritation. After

 

 

handling logs, wash your hands gently with soap and wa-

 

 

ter.

TOP LEFT LOG

REAR LOG

TOP RIGHT LOG

CENTER LOG

 

FRONT RIGHT LOG

 

 

 

FRONT LEFT LOG Figure 15

 

 

 

LOG SET DIAGRAM - A

1 - REAR LOG

 

 

4 - TOP LEFT LOG

3 - TOP RIGHT LOG

The Gas Log Kit contains the following:

 

 

 

 

1)Rear Log

2) Center Log

3)Top Right Log

4)Top Left Log

5)Front Left Log

6) Front Right Log

5 - FRONT LEFT LOG

6 - FRONT RIGHT LOG

Figure 16

2 - CENTER LOG

 

Page 18

22618-17-0308

Page 18
Image 18
Empire Comfort Systems PV-28SV50-BN, PV-28SV55-CN, GN, GP)-1, CP LOG SET Installation Instructions, Log Installation All Logs

BP)-1, GN, PV-28SV50-BN, CP, GP)-1 specifications

Empire Comfort Systems is renowned for producing high-quality heating products, and the GP-1, GN, PV-28SV55-CN, CP, BP-1 is no exception. This comprehensive heating solution combines innovative technologies with practical features designed to enhance comfort and efficiency in various environments.

The GP-1 model is a direct vent gas log set that showcases the brand's commitment to producing clean and efficient heating options. One of its standout characteristics is its ability to operate without needing a traditional chimney, making it an excellent choice for homes where a fireplace may not have been previously installed. The direct vent design uses outside air for combustion, ensuring optimal efficiency while minimizing energy loss.

What sets the GN model apart is its impressive output capacity. Engineered for robustness, this gas heater can deliver significant warmth, making it ideal for larger spaces or homes in colder climates. The unit is designed to heat quickly and evenly, providing a comfortable living environment without drastic fluctuations in temperature.

The PV-28SV55-CN brings advanced technology into the fold with its vent-free capabilities. This feature allows for installation flexibility, as it can be positioned in various spaces without requiring venting to the outside. This characteristic not only simplifies installation but also allows users to enjoy the warmth without the hassle of dealing with exterior vents.

The CP and BP-1 models focus on user convenience and safety. Both are equipped with state-of-the-art control systems that allow users to manage their heating options easily. The intuitive controls facilitate temperature adjustments, ensuring users can maintain their preferred heat levels effortlessly. Additionally, safety features such as oxygen depletion sensors (ODS) provide peace of mind by automatically shutting off the unit if unsafe conditions arise.

In terms of design, Empire Comfort Systems has ensured that these models fit seamlessly into any décor. The stylish aesthetic, combined with a variety of finish and style options, allows homeowners to choose a gas fireplace that complements their interior design.

In conclusion, the Empire Comfort Systems GP-1, GN, PV-28SV55-CN, CP, BP-1 represents a harmonious blend of advanced technology, safety features, and elegant design. It is an exemplary choice for anyone seeking to enhance their home's warmth and efficiency while enjoying the beauty and ambiance a gas heating solution can provide. With a focus on comfort, reliability, and aesthetic appeal, these models stand out as top contenders in the market for home heating solutions.