MAIN BURNER FLAME CHARACTERISTICS

SR-10T, SR-18T and SR-30T Main Burner Flame (Figure12) The main burner flame will have a red-orange glow over the surface of the ceramic plaques. A few small, hairline cracks may form over the surface of the ceramic plaques or at the edges of the ceramic plaques where they have been cemented into position on the burner assembly frame. These small, hairline cracks will not affect the operation or performance of the ceramic plaques. Only, when large cracks develop, with blue flames escaping from the large cracks, should you contact your QUALIFIED SERVICE PERSON.

Ared-orange haze that is visible on the ceramic plaques is acceptable. Ablue flame that rolls out at the top of the ceramic plaques indicates an accumulation of dust, lint or spider webs inside the casing assembly and main burner assembly. Use the following procedure to inspect the casing assembly and main burner assembly.

1.Turn OFF gas supply to the heater.

2.Turn OFF electric supply to the heater if optional blower is installed in heater.

3.Remove lower louver from casing assembly ( 2 screws).

4.Remove reflector from casing assembly (2 screws).

5.Inspect interior of casing assembly for accumulation of dust, lint or spider webs. If necessary, clean interior of casing assembly with a vacuum cleaner or apply air pressure. Do not damage any components within casing assembly when you are cleaning.

6.Remove pilot bracket from main burner assembly (2 screws).

7.Pivot pilot bracket with attached pilot away from main burner assembly (do not damage pilot tubing).

8.Inspectmainburnerorifice(s)throughtherectangularopening(s) in the venturi (throat) of the main burner(s). Dust, lint and spider

webs can accumulate on top of the main burner orifice(s). If necessary, clean main burner orifice(s) with a vacuum cleaner or apply air pressure. To thoroughly clean the main burner orifice(s) proceed to Step 9.

9.Disconnect supply tubing from orifice holder(s).

10.Remove orifice holder from venturi of main burner assembly (1 screw for each orifice holder).

11.Remove main burner orifice from orifice holder.

12.Apply air pressure through main burner orifice and orifice holder to remove dust, lint or spider webs.

13.Apply air pressure into ceramic plaque(s) to remove dust, lint or spider webs.

14.As parts are being replaced in reverse order, check for gas leaks at all gas connections before lower louver is replaced onto casing assembly.

SR-30T SHOWN

Figure 12

16941-5-0907

Page 13

Page 13
Image 13
Empire Comfort Systems SR-10T-3 installation instructions Main Burner Flame Characteristics

SR-10T-3 specifications

The Empire Comfort Systems SR-10T-3 is a highly efficient, innovative heating solution designed to meet the demands of modern living. This product exemplifies a commitment to quality, reliability, and user-friendly operation, making it an ideal choice for both residential and commercial spaces.

One of the standout features of the SR-10T-3 is its advanced infrared heating technology. This innovation allows the heater to warm objects and people directly rather than just heating the surrounding air, resulting in quick and efficient heat distribution. This means users can enjoy a comfortable environment almost immediately after turning the unit on, reducing wait times that are typically associated with conventional heating methods.

The design of the SR-10T-3 is another highlight. It boasts a compact and sleek profile that can seamlessly integrate into various settings without taking up excessive space. Moreover, this model is available in multiple finishes to complement any décor, ensuring it not only functions effectively but also enhances the aesthetic of the room.

The SR-10T-3 is equipped with an adjustable thermostat, allowing users to customize their heating experience according to their specific needs. This feature promotes energy efficiency, as it helps prevent unnecessary energy consumption by automatically regulating the temperature. In addition, the heater is designed with convenience in mind, incorporating a safety shut-off feature that activates if the unit overheats or tips over, ensuring peace of mind during use.

Durability is another defining characteristic of the Empire Comfort Systems SR-10T-3. Made with high-quality materials, this heater is built to withstand the rigors of daily use while maintaining optimal performance. Its user-friendly controls and straightforward installation process also contribute to its appeal, making it accessible for anyone looking to enhance their heating solutions.

In conclusion, the Empire Comfort Systems SR-10T-3 is an exceptional choice for those seeking an efficient and stylish heating solution. With its infrared heating technology, adjustable thermostat, and durable construction, it stands out in its category, promising reliability and comfort for years to come. Its thoughtful design and commitment to efficiency make it a noteworthy investment for any heating needs.