Empire Comfort Systems SR-10T-3 installation instructions SR-10TCLEARANCES

Models: SR-10T-3

1 24
Download 24 pages 18.59 Kb
Page 8
Image 8
SR-10T CLEARANCES

SR-10T CLEARANCES

When facing the front of the appliance the following minimum clearances to combustible construction must be maintained.

Left side 6 inches (152mm). Right side 6 inches (152mm). Do not install in alcove or closet.

Rear wall 0 inches (0mm). Ceiling 24 inches (610mm). Minimum vertical clearance from a projection above the appliance (shelves, window sills, etc.) 14 inches (356mm). Maximum horizontal extension of projection above the appliance 12 inches (305mm).

Floor (top surface of carpeting, tile, etc.) 2 inches (51mm). Provide adequate clearances around air openings.

Adequate accessibility clearances for purposes of servicing and proper operation must be provided.

(610mm)

Figure 4 (SR-10T)

(356mm) 6”

(152mm)(152mm)

(51mm)

Figure 3 (SR-10T)

Page 8

16941-5-0907

Page 8
Image 8
Empire Comfort Systems SR-10T-3 installation instructions SR-10TCLEARANCES