Empire Comfort Systems VFP32FP, VFP36FP, 31)L(N, P)-1 Operation Instructions/Flame Appearance

Models: VFP32FP VFP36FP P)-1 31)L(N 21)L(N

1 28
Download 28 pages 51.45 Kb
Page 16
Image 16
OPERATION INSTRUCTIONS/FLAME APPEARANCE

OPERATION INSTRUCTIONS/FLAME APPEARANCE

Flames from the pilot (rear right back side of the pan burner) as well as the main flame should be visually checked as the log set is installed.

In normal operation at full rate after 10 to 15 minutes, the flame appearance should be sets of yellow flames.

NOTE: All flames will be random by design, flame height will go up and down.

Glowing embers (rock wool) can cover the pan burner in between the front and middle logs, but very little is necessary to cover this area. Excess ember material causes the yellow flame to become orange and stringy. Apply just enough to obtain slow glow and a gold yellow flame.

Avoid any drafts that alter burner flame patterns. Do not allow fans to blow directly into fireplace. Do not place a blower inside the burner area of the firebox. Ceiling fans may create drafts that alter flame patterns. Sooting and improper burning will result.

During manufacturing, fabricating and shipping, various components of this appliance are treated with certain oils, films or bonding agents. These chemicals are not harmful, but may produce annoying smoke and smells as they are burned off during the initial operation of the appliance, possibly causing headaches or eye or lung irritation. This is a normal and temporary occurrence.

The initial break-in operation should last 2-3 hours with the burner at the highest setting. Provide maximum ventilation by opening windows or doors to allow odors to dissipate. Any odors remaining after this initial break-in will be slight and will disappear with continued use.

PERIODIC CLEANING – Refer to parts diagram for location of items discussed below.

Do not use cleaning fluid to clean logs or any part of heater.

Logs - brush with soft bristle brush or vacuum with brush attachment.

Remove loose particles and dust from the burner areas, controls, piezo covers and grate. Don’t remove ceramic media from inside burner box.

Inspect and clean burner air intake hole. Remove lint or particles with brush. Failure to keep air intake hole clean will result in sooting and poor combustion.

ANNUAL CLEANING/INSPECTION – Refer to parts diagram for location of items discussed below.

Inspect and clean burner air intake hole. Remove lint or particles with vacuum or brush. Failure to keep air intake hole clean will result in sooting and poor combustion.

Inspect and clean all burner ports.

Inspect ODS pilot for operation and accumulation of lint at air intake holes.

Verify flame pattern and log placement for proper operation.

Verify smooth and responsive ignition of main burner.

Check level of ceramic media in burner. Burner should be full, up to the level of openings in burner top.

Page 16

20101-0-0306

Page 16
Image 16
Empire Comfort Systems VFP32FP, VFP36FP, 31)L(N, P)-1, 21)L(N installation instructions Operation Instructions/Flame Appearance