TROUBLESHOOTING

SYMPTOMS - POSSIBLE CAUSES AND CORRECTIONS

Turn appliance OFF and allow to cool before servicing. Only a qualified service person should service and repair the heater.

1.When ignitor button is pressed, there is no spark at ODS/ pilot.

a.Ignitor electrode positioned wrong - Replace pilot.

b.Ignitor electrode is broken - Replace pilot.

c.Ignitor electrode not connected to ignitor cable - Reconnect ignitor cable.

d.Ignitor cable pinched or wet. Keep ignitor cable dry - Free ignitor cable if pinched by any metal or tubing.

e.Broken ignitor cable - Replace ignitor cable.

f.Bad piezo ignitor - Replace piezo ignitor.

2.Appliance produces unwanted odors.

a.Appliance burning vapors from paint, hair spray, glues, etc. - Ventilate room. Stop using odor causing products while heater is running.

b.Gas leak - Locate and correct all leaks.

3.Appliance shuts off during use. (Pilot and main burner are off.)

a.Not enough fresh air is available for ODS/pilot to operate

-Open window and/or door for ventilation.

b.Low line pressure - Contact local gas company.

c.ODS/pilot is partially clogged - Clean ODS/pilot.

d.Defective thermocouple - Replace pilot.

4.Appliance shuts off during use. (Pilot stays on.)

a.Low line pressure - Check line pressure to the valve.

b.Defective thermopile - Check pilot flame, check wire connections, output should be a minimum of 325 millivolts across. TH/TP and TP terminals with ON/OFF switch off.

5.Gas odor even when control knob is in OFF position.

a.Gas leak - Locate and correct all leaks.

b.Control valve defective - Replace control valve.

6.When ignitorbutton is pressed, there is spark at ODS/pilot, but no ignition.

a.Gas supply turned off or manual shutoff valve closed

-Turn on gas supply or open manual shutoff valve.

b.Control knob not in PILOT position - Turn control knob to PILOT position.

c.Control knob not pressed in while in PILOT position

-Press in control knob while in PILOT position.

d.Air in gas lines when installed - Continue holding down control knob. Repeat igniting operation until air is removed.

e.ODS/pilot is clogged - Replace ODS/pilot assembly or get it serviced.

f.Gas regulator setting is not correct - Replace gas regulator.

7.ODS/pilot lights but flame goes out when control knob is released.

a.Control knob not fully pressed in - Press in control knob fully.

b.Control knob not pressed in long enough -After ODS/pilot lights, keep control knob pressed in 30 seconds.

c.Manual Shutoff valve not fully open - Fully open manual shutoff valve.

d.Thermocouple connection loose at control valve - Hand tighten until snug, then tighten 1/4 turn more.

e.Pilot flame not touching thermocouple, which allows thermocouple to cool, causing pilot flame to go out. This problem could be caused by either low gas pressure or dirty or partially clogged ODS/pilot - Contact local gas company.

f.Thermocouple damaged - Replace thermocouple.

g.Control valve damaged - Replace control valve.

8.Burner does not light after ODS/pilot is lit.

a.Burner orifice clogged - Clean burner or replace main burner orifice.

b.Burner orifice diameter is too small - Replace burner orifice.

c.Inlet gas pressure is too low - Contact qualified service person.

9.If burning at main burner orifice occurs (a loud, roaring blow torch noise).

a.You must turn off burner assembly and contact a qualified service person.

b.Manifold pressure is too low - Contact local gas company.

c.Burner orifice clogged - Clean burner or replace burner orifice.

10.Logs appear to smoke after initial operation.

a.Vapors from paint or curing process of logs - Problem will stop after a few hours of operation. Run the heater with the damper open if you have one, or open a window for the first few hours.

Log heater is intended to be smokeless. Turn OFF heater and call qualified service person.

11.Heater produces a whistling noise when main burner is lit.

a.Turning control knob to HIGH position when main burner is cold - Turn control knob to LOW position and let warm up for a minute.

b.Air in gas line - Operate burner until air is removed from line. Have gas line checked by local gas company.

c.Dirty or partially clogged burner orifice - Clean burner or replace burner orifice.

12.No gas to pilot.

a.LP-regulator shut down due to inlet pressure too high - Verify LP tank regulator is installed and set at 11" to 13" w.c. Replace regulator on heater.

If the gas quality is bad, your pilot may not stay lit, the burners may produce soot and the heater may backfire when lit. If the gas quality or pressure is low, contact your local gas supplier immediately.

20101-0-0306

Page 21

Page 21
Image 21
Empire Comfort Systems VFP32FP, VFP36FP Appliance produces unwanted odors, Appliance shuts off during use. Pilot stays on

VFP32FP, VFP36FP, P)-1, 31)L(N, 21)L(N specifications

Empire Comfort Systems is a well-recognized name in the heating and appliance industry, known for its quality products and innovative technologies. Among their impressive offerings are the VFP32FP, VFP36FP, and VFP21)L(N,31)L(N,P)-1 series gas fireplaces, designed to provide warmth, ambiance, and efficiency for modern homes.

The VFP32FP is a versatile unit that seamlessly blends into various room designs. With a 32-inch viewing area, it showcases a beautiful flame while offering an impressive heat output. This model features a heat exchanger that ensures maximum warmth reaches the living space without excessive energy use. The VFP32FP also comes equipped with a millivolt system that allows for easy operation, even during power outages.

The VFP36FP is ideal for those seeking a larger fireplace experience. With a 36-inch viewing area, it not only enhances the aesthetic of any space but also produces substantial heat to combat chilly nights. What sets the VFP36FP apart is its high-efficiency design, ensuring lower emissions and reduced gas consumption. The unit's adjustable flame and thermostat controls allow homeowners to customize their heating needs easily.

Empire's VFP21)L(N,31)L(N,P)-1 offers a compact yet powerful heating solution. This fireplace is perfect for smaller spaces without sacrificing performance. It comes with a robust design and various decorative options to match any interior style. The advanced technology utilized in this model ensures efficient heat distribution, making it a practical choice for cozy living areas.

All models boast a range of features that enhance usability and comfort. They come with convenient remote control options, allowing for easy operation from anywhere in the room. The emphasis on safety is evident through the inclusion of glass safety screens and built-in safety shut-off systems.

Empire Comfort Systems has committed to sustainability, and these fireplaces exemplify that dedication. Each model is engineered to provide eco-friendly heating solutions, contributing to reduced carbon footprints while delivering exceptional performance.

In summary, the Empire Comfort Systems VFP series, including the VFP32FP, VFP36FP, and VFP21)L(N,31)L(N,P)-1, represents the perfect blend of innovation, efficiency, and beauty. With robust features and cutting-edge technology, these gas fireplaces fulfill the heating needs of contemporary homes while enhancing their visual appeal. Homeowners can enjoy warmth, style, and peace of mind knowing they have chosen a reliable and efficient product from Empire Comfort Systems.