PILOT FLAME CHARACTERISTICS

PILOT FLAME CHARACTERISTICS

Figures 13 and 15 show a correct pilot flame pattern. The correct flame will be blue and will extend beyond the thermocouple. The flame will surround the thermocouple just below the tip. A slight yellow flame may occur where the pilot flame and main burner flame meet. Figures 14 and 16 show an incorrect pilot flame pattern. The incorrect pilot flame is not touching the thermocouple. This will cause the thermocouple to cool. When the thermocouple cools, the heater will shut down.

VFP(32,36)FP(30,31) PILOT

Correct Pilot Flame Pattern

Figure 13

Incorrect Pilot Flame Pattern

Figure 14

If pilot flame pattern is incorrect, as shown in Figure 14

See Troubleshooting, page 21.

VFP(32,36)FP(20,21) PILOT

Correct Pilot Flame Pattern

Figure 15

Incorrect Pilot Flame Pattern

Figure 16

If pilot flame pattern is incorrect, as shown in Figure 16

See Troubleshooting, page 21.