JUNCTION BOX WIRING INSTALLATION INSTRUCTIONS

JUNCTION BOX WIRING INSTALLATION INSTRUCTIONS

CAUTION: ALL WIRING SHOULD BE DONE BY A QUALIFIED ELECTRICIAN AND SHALL BE IN COMPLIANCE WITH ALL LOCAL, CITY AND STATE BUILDING CODES. BEFORE MAKING THE ELECTRICAL CONNECTION, MAKE SURE THAT MAIN POWER SUPPLY IS DISCONNECTED. THE APPLIANCE, WHEN INSTALLED, MUST BE ELECTRICALLY GROUNDED IN ACCORDANCE WITH LOCAL CODES OR, IN THE ABSENCE OF LOCAL CODES, WITH THE NATIONAL ELECTRICAL CODE ANSI/NFPA 70 (LATEST EDITION).

A factory installed junction box is located on the lower right hand side of the fireplace. Wiring must be fed to the junction box and attached to the receptacle that is provided. Remove the knockout in the installed junction box to accept wiring into the junction box. Install a UL listed cable clamp (not supplied) in the knockout hole. Leave approximately 6" of wire in the junction box for connection.

Attach black wire to one side of the receptacle and white wire to opposite side of receptacle. The ground wire should be attached to the green (neutral) screw.

Install the receptacle into the junction box. Attach cover plate.

Figure 22

OPTIONAL BRICK LINER INSTALLATION INSTRUCTIONS

Brick Liner VPP32A and VPP36A

1.Remove screen from fireplace.

2.Remove branch log and rear log from burner assembly.

3.Insert back panel into firebox.

4.Insert one (1) side panel into firebox.

5.Use two (2) brick panel brackets to secure side panel. Align clearance hole on brick panel bracket with screw hole in the left or right interior, top and bottom of firebox. Use two (2) 10 x 1/2" screws to attach brick panel bracket to interior top and bottom of firebox.

6.Repeat steps 4 and 5 to install second side panel.

7.Replace rear log and branch log onto burner assembly.

8.Replace screen onto fireplace.

9.Installation of optional brick liner is completed.

PART NAME

VPP32A

VPP36A

 

 

 

 

 

 

 

 

PART NO.

PART NO.

BRICK PANEL SIDE - LEFT

R8692

R8695

BRICK PANEL SIDE - RIGHT

R8693

R8696

BRICK PANEL BACK

R8694

R8697

BRICK PANEL BRACKET (4 REQ’D)