England's Stove Works 10-CDV, 49-SHC22, 49-TRC22 Floor and Wall Protection, Floor Protection

Models: 49-SHC22 10-CDV 49-TRC22

1 31
Download 31 pages 11.4 Kb
Page 12
Image 12

Freestanding Corn/Pellet Installation

Caution: Follow the pipe manufacturer’s installation instructions and directions for passing through combustible walls and ceilings. Check local codes in your area.

Must have

minimum 3”

adapter before tee

for longer run. For shorter run (such as Masonry Connection below), tee alone is acceptable.

Illustration 1

Our Part AC-33000

is acceptable for through-the-wall installation.

(We recommend 4”

for 2500+ ft. installations.)

Basement Installation should be performed by

professional installer. Use 3” metal pipe and coupler for Outside Combustion Air. Minimum 3’ clearance from ground to the Pellet Vent Exhaust Pipe.

1.If 3” flue pipe exceeds 15’ in length, increase to 4” flue pipe for remaining flue connections.

2.Total flue length should not exceed 35’.

3.Horizontal run not to exceed 4’.

4.Floor protector required: Min. size 36” x 36”.

5.If the total run of outside air connection exceeds 6’, if more than 2 elbows are used, or if a basement install, use 3” metal pipe (and coupler) instead.

6.Outside Air is mandatory for proper safe operation.

FLOOR AND WALL PROTECTION

Floor Protection

If your floor is constructed of a non-combustible material such as brick or concrete, there is no need for floor protection. If the floor is constructed of a combustible material such as hardwood, linoleum, or carpet, then you will be required to use floor protection between the unit and the combustible. The protection should be U.L. approved or equal, and should be large enough to provide a minimum of six inches (6”) behind and on both sides of the stove. The clearance in front of the stove should be at least six inches (6”). This freestanding pellet unit will need a minimum 36” x 36” floor protector.

Wall Protection

From the rear of this stove only three inches (3”) of clearance is required to paneling, wallpaper or drywall. The same clearance (3”) is required to a corner wall. Six inches (6”) would be required to a sidewall. Alcove clearances: Six inches (6”) is required to an alcove sidewall; three inches (3”) is required to an alcove backwall, and seventeen inches (17”) is required to an alcove ceiling. The corn vent pipe would require the standard three inches (3”) clearance, or as recommended by the manufacturer. Normally additional wall protection is not required with this type unit.

12

Page 12
Image 12
England's Stove Works 10-CDV, 49-SHC22, 49-TRC22 operation manual Floor and Wall Protection, Floor Protection