OPERATING INSTRUCTIONS

CAUTION: DO NOT OPERATE WITH THE DOOR OPEN.

If door is left open (approximately) two minutes, unit will stop feeding and fire will go out.

Do not burn trash (paper bags, etc.) in this unit.

This stove has an induced draft system and is designed to operate continuously, as frequent shutdown is not required. The setting of the “Heat Range” touch pad will control the heat output and the amount of fuel the unit will burn (see “Control Board” section and Illustration 4). Note: This stove is using solid fuel and will not restart automatically.

*NOTE: Blower Speed will automatically be adjusted to the desired Heat Range that you select.

START- UP PROCEDURES

Caution - Never use gasoline, lantern fuel, charcoal lighter fluid, diesel fuel, or any other flammable liquid to start the fire.

When first starting your corn/pellet stove, place approximately one (1) cup of hardwood pellets in the fire pot. Place a small amount of starter gel or fire starter on top of the pellets and light, leaving the door cracked slightly for the first 2 minutes. After the first two minutes, close the door and press the “ON” button located on the Control Panel.

The Heat Range and Blower Speed will automatically be set to setting “5,” to ensure that proof of fire is detected. During the 20 minute start-up period the user can set the controls to a desired heat setting, and after the 20 minute start-up the unit will operate at that user setting.

NOTE: On the “first fire” (the first time you burn the unit), the Control Panel should be set at a “5” Heat Range and “5” Blower Speed for at least 3 hours to allow the unit to “cure” as the oils from the manufacturing process burn off. Windows and doors in the home should be opened to help ventilate as these oils burn off.

NOTE: If the unit does not start, DO NOT try to restart the unit until it has cooled completely down. If the unit does not start or maintain a fire, you will receive an E-2in the Heat Range and Blower Speed window of the Control Board. If this occurs, wait until unit has cooled completely down and repeat these steps.

FUEL NOT FEEDING CORRECTLY

If the fuel is not feeding correctly, the feed auger could possibly be misaligned due to factors such as rough handling during shipping. If you suspect your feed auger is misaligned, call Customer Service at (800) 245-6489.

13

Page 13
Image 13
England's Stove Works 49-SHC22, 10-CDV, 49-TRC22 operation manual Operating Instructions, START- UP Procedures