Model P Nomenclature

Selection

Procedure

Model P Nomenclature

 

 

 

 

 

 

 

 

 

 

 

 

 

Digit 15 – Fan Guard

 

 

UHP

A

0 4 2

 

P

4

C

A

A

1

T

A

R

C

A

D

B

 

E

 

 

 

 

 

123

4

 

5 6 7

 

8

9

10

11

12

13

14

15

16

17

18

19

20

21

Digit 16 – Unit Coating

 

 

 

 

 

 

 

 

 

Digits 1,2,3 – ProductType

 

 

 

 

Digit 10 – Design Sequence

 

 

Digit 17 – Diffuser

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Digit 4 – Development Sequence

 

 

 

Digit 11 –Tube Material

 

 

 

Digit 18 – Manual Starter

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Digits 5,6,7 – Unit Size

 

 

 

 

 

Digit 12 – Fin Material

 

 

 

 

Digit 19 – Speed Controller (115/60/1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Digit 8 – CoilType

 

 

 

 

 

 

Digit 13 –Voltage

 

 

 

 

 

standard motors)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Digit 9 – Fin Series

 

 

 

 

 

 

Digit 14 – MotorType

 

 

 

 

Digit 20 –Thermostats

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Digit 21 – Subbase

 

 

Table SP-7 – Factors For Determining Steam Capacity Of Model P Projection Unit Heaters AtVarious Pressures AndTemperatures

 

 

Table Based on 2 PSIG and 60 F Entering Air

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Steam

 

 

 

 

 

 

 

 

 

 

 

 

 

Temperature of Entering Air (F)

 

 

 

 

 

Pressure PSIG

 

-10

 

 

0

 

10

 

20

 

30

 

40

50

60

70

80

90

100

 

 

 

0

 

 

1.49

 

1.41

 

1.33

 

1.25

 

1.18

1.11

1.03

0.96

0.90

0.83

0.76

0.69

 

 

 

2

 

 

1.52

 

1.45

 

1.37

 

1.29

 

1.22

1.15

1.07

1.00

0.93

0.86

0.80

0.73

 

 

 

5

 

 

1.58

 

1. 50

 

1.42

 

1.34

 

1.27

1.20

1.12

1.05

0.98

0.91

0.85

0.78

 

 

 

10

 

 

1.64

 

1.57

 

1.49

 

1.41

 

1.34

1.27

1.19

1.12

1.05

0.98

0.91

0.85

Draw-

 

15

 

 

1.70

 

1.62

 

1.55

 

1.47

 

1.40

1.32

1.25

1.18

1.11

1.04

0.97

0.90

Through

 

20

 

 

1.75

 

1.67

 

1.60

 

1.52

 

1.45

1.37

1.30

1.23

1.16

1.09

1.02

0.96

Unit

30

 

 

1.83

 

1.75

 

1.68

 

1.61

 

1.53

1.46

1.39

1.32

1.25

1.18

1.11

1.04

 

 

 

40

 

 

1.90

 

1.82

 

1.75

 

1.68

 

1.61

1.53

1.46

1.39

1.32

1.25

1.18

1.11

 

 

 

50

 

 

1.96

 

1.87

 

1.81

 

1.74

 

1.67

1.59

1.52

1.45

1.38

1.31

1.24

1.17

 

 

 

60

 

 

2.02

 

1.94

 

1.87

 

1.79

 

1.72

1.64

1.57

1.50

1.43

1.36

1.29

1.22

 

 

 

 

70

 

 

2.07

 

1.99

 

1.92

 

1.84

 

1.76

1.69

1.62

1.55

1.47

1.40

1.33

1.27

 

 

 

75

 

 

2.10

 

2.02

 

1.94

 

1.86

 

1.79

1.71

1.64

1.57

1.49

1.42

1.36

1.29

Note:

To determine the Btu per hour capacity of a Model P projection unit heater at any steam pressure and entering air temperature, multiply rated capacity at 2 psig steam 60 F entering air (Table SP-5) by factor from above table.

Additional Selection Data

Motor and Fan Speeds

Motor and fan speeds are selected to provide efficient performance.The solid-state speed control will provide an infinite number of speeds between the highest and the lowest cataloged fan speeds.The speed control is not calibrated in specific fan speeds. For use on units with 115 volt/60 cycle/

1 phase, 1/8 hp and smaller standard motors only.

Standard and Bypass Units Standard models meet most requirements and are most economical. Bypass units meet conditions as mentioned above, and are also used where low final temperature is specified.

25 and 50 Cycle Unit Heat Capacities Table SP-8 shows the Btu, cfm, and the hp required on unit heaters when operated on 25 or 50 cycle circuits. The multipliers inTable SP-8 may be applied to standard 60 cycle unit capacities to determine the capacities of the same unit when operating on

25 or 50 cycle current.These multipliers may be used on units cataloged at 1050 to 1150 RPM.

For the smallerTrane Unit Heaters cataloged at 1550 RPM, the capacity data in the catalog may be applied to either 25 or 50 cycle service.

Table SP-8 – Factors for Determining Unit Heater Capacities at 25 or 50 Cycles

RPM

MultiplierTo Be AppliedTo

60-Cycle 1100 RPM Ratings

25 CY

50 CY

BTU

CFM

HP

1425

1425

1.17

1.25

1.95

 

950

.87

.833

.572

710

710

.7

.623

.242

Table SP-9 – Properties of Steam

Gauge Pressure

Temp.

Latent

Lbs.

F

Heat

2

219

965

5

227

960

10

239

952

15

250

945

20

259

939

25

267

933

30

274

928

40

287

919

50

298

911

60

307

904

70

316

897

75

320

891

18

UH-PRC001-EN

Page 18
Image 18
Trane UH-PRC001-EN manual Additional Selection Data, Model P Nomenclature, Motor and Fan Speeds, Selection Procedure