GAS RATINGS
TYPE OF GAS | → | NATURAL | L.P./PROPANE |
MAX. INPUT |
| 34,500 BTU/HR | 30,000 BTU/HR |
MIN. INPUT |
| 20,000 BTU/HR | 20,000 BTU/HR |
MANIFOLD PRESSURE | 3.5” W.C. | 10” W.C. | |
M/FOLD PRESSURE LOW | 1.0/3.5” W.C. | 4.5/10.0” W.C. | |
MIN. INLET PRESSURE | 5.0” W.C. | 11.0” W.C. | |
MIN. SUPPLY PRESSURE | 5.5” W.C. | 11” W.C. | |
MAX. SUPPLY PRESSURE | 10.5” W.C. | 14” W.C. | |
ORIFICE SIZE |
| #34 | #51 |
MINIMUM CLEARANCES TO COMBUSTIBLES
THIS APPLIANCE SHALL BE INSTALLED ON A METAL OR WOOD PANEL THAT EXTENDS THE FULL WIDTH AND DEPTH OF THE APPLIANCE WHEN INSTALLED ON A COMBUSTIBLE SURFACE OTHER THAN WOOD.
WARNING: WHEN USED WITHOUT FRESH AIR THIS HEATER MAY GIVE OFF CARBON MONOXIDE, AN ODORLESS POISONOUS GAS.
OPEN A WINDOW AN INCH OR TWO FOR COMBUSTION AIR.
England’s Stove Works highly recommends the use of smoke detectors and
Carbon Monoxide detectors with any hearth product, including this unit. Follow all manufacturer’s instructions when using smoke or Carbon Monoxide detectors.