MAIN BURNER IGNITION

MAIN BURNER IGNITION

1)Upon lighting, release knob and turn further counterclockwise to “ON” position (both pilot and gas flow).

2)Turn on all electric power to appliance.

TO TURN GAS OFF TO APPLIANCE

1)Set thermostat to the lowest setting.

2)Turn off all electric power to the appliance if service is to be performed.

3)Remove control access panel.

4)Turn knob “A” clockwise until it stops.

3)Set thermostat to desired setting.

4)To turn off the gas to the main burner only, turn gas control clockwise to pilot.

5)Press down slightly and continue turning clockwise from pilot position to “OFF”.

6)Replace control access panel.

MAINTENANCE INSTRUCTIONS

1)Periodic visual checks of the pilot should be conducted to ensure the flame is present except when the valve control knob is in the “OFF” position.

2)The pilot flame should always be present when the heater is in operation, and should just touch the top of the thermocouple tip.

3)If the pilot flame does not touch the thermocouple, then the main burner is unlikely to function properly.

4)Remove the logs from the grate assembly and vacuum any loose particles from the grate and burner area each month.

5)Flame Appearance

In normal operation at the full rate, after 15 minutes the flame appearance should be observed (See diagram).

Flame Appearance

6)All components (see parts list) are available directly through the factory. Write or telephone:

England’s Stove Works, Inc. Cust. Service Department P.O. Box 206

Monroe, VA 24574

(Parts Orders: 800-516-3636)

(FAX: 434-929-4810)

7)Installation and all repairs should be done by a qualified service person. The appliance should be inspected before use and at least annually by a qualified service person. It is imperative that control compartments, burners and circulating air passageways of the appliance be kept clean. Note: More frequent cleaning may be required due to excessive lint from carpeting, bedding material, etc.

WARNING: DO NOT ADJUST THE GAS ORIFICE. KEEP AREA CLEAR AND FREE FROM COMBUSTIBLE MATERIALS, GASOLINE AND OTHER FLAMMABLE VAPORS AND LIQUIDS.