Alarm Configuration

13.Click the Apply button to set your changes. If you have made any errors in configuring alarm parameters (using an invalid value in any field, leaving a field blank, or selecting an alarm variable which is not resident on the device), an error window with the appropriate message will appear. Correct the noted problem(s), and click the Apply button again.

The window remains open so that you may configure additional new alarms or modify existing ones; remember, you can double-click on any alarm in the Alarms Watch list in the main Alarm/Event window to display its parameters in the Create/Edit Alarms window. When you have finished configuring your alarms, click on the Cancel button to close the window.

Creating and Editing an Event

The Create/Edit Events window (Figure 4-5, on page 4-21) — like the Create/Edit Alarms window — allows you to both create new events and edit existing ones. When you click on the Create/Edit button in the Events Watch list, the Create/Edit Events window will display the parameters of the event which is currently highlighted in the list. (If no events have yet been configured, a set of default parameters will be displayed.) All of these parameters are editable: to change an existing event, edit any parameter except the Index value; to create an entirely new event, simply assign a new Index number. The ability to assign index numbers allows you to quickly and easily create a number of similar events without having to close, then re-open the window or re-assign every parameter.

The main Alarm/Event window remains active while the Create/Edit Events window is open; to edit a different event (or use its settings as the basis of a new event), simply double-click on the event you want to use in the main Events Watch list, and the Create/Edit Events window will update accordingly.

If the Create/Edit Actions window is also open, it too will update to display the actions

TIP associated with the event currently selected in the main Alarm/Event window. See Adding Actions to an Event, on page 4-23, for more information on the actions feature.

To configure an event:

1.If you wish to modify an existing event or create a new event based on the parameters of an existing one, be sure the event of interest is highlighted in the Events Watch list, then click on the Create/Edit button at the top of the Events Watch portion of the RMON Advanced Alarm/Event window. The Create/Edit Events window, Figure 4-5, will appear.

If you wish to create an entirely new event, it doesn’t matter which existing event (if any) is highlighted when you open the Create/Edit Events window; although the window will, by default, display the parameters of whichever event is currently selected, all parameters are editable and can be configured as desired.

4-20

Advanced Alarm Configuration

Page 136
Image 136
Enterasys Networks 700 manual Creating and Editing an Event

700 specifications

Enterasys Networks, a key player in the networking and security industry, offers an extensive range of solutions, among which is the Enterasys Networks 700 series. The Enterasys 700 series is designed to meet the demands of modern networking environments while providing a robust set of features, high performance, and scalability that appeals to organizations of various sizes.

One of the main features of the Enterasys 700 series is its ability to deliver high-speed connectivity, which supports multiple Gigabit Ethernet ports. This ensures that organizations can efficiently handle bandwidth-intensive applications and a growing number of connected devices. The series is designed to facilitate seamless and reliable data transmission, making it suitable for environments that require consistent uptime and performance.

The Enterasys 700 series is built around advanced security protocols that are essential for protecting organizational data. These security features include integrated firewalls, intrusion detection systems, and comprehensive access control policies. This ensures that sensitive information remains secure from internal and external threats while providing IT administrators with the tools needed to manage security policies effectively.

Another notable characteristic of the Enterasys 700 series is its intelligent networking capabilities. The integration of advanced Quality of Service (QoS) mechanisms allows network administrators to prioritize critical applications, ensuring optimal performance for mission-critical services. This capability is especially important in environments that host multiple applications, as it empowers organizations to manage bandwidth efficiently and maintain service quality.

The Enterasys 700 series also incorporates advanced network management solutions, enabling centralized control and monitoring. This feature simplifies the administration of network resources, allowing IT teams to quickly diagnose issues and deploy solutions as needed. The user-friendly interface and comprehensive reporting tools further enhance the management experience, providing insights into network performance and health.

Furthermore, the Enterasys Networks 700 series is designed with scalability in mind. Organizations can easily expand their network infrastructure without the need for significant overhauls, accommodating future growth and technological advancements. This flexibility not only saves costs but also ensures that organizations remain competitive in an ever-evolving digital landscape.

In summary, the Enterasys Networks 700 series offers a rich suite of features and technologies that cater to modern networking needs. Its high-speed connectivity, robust security measures, intelligent networking capabilities, comprehensive management tools, and scalability make it an excellent choice for organizations looking to enhance their network infrastructure. Whether for small businesses or large enterprises, the Enterasys 700 series stands out as a reliable and versatile networking solution.