Checklist

Table 3-1 Troubleshooting Checklist (continued)

Problem

Recommended Action

 

 

The Single-Port Power Over

Verify that you are using a standard UTP

Ethernet Adapter operates but

Cat. 5 or greater cable, including all 8 wires

one of the powered devices

(4 pairs.)

does not work.

Try using a different Ethernet cable. If it works,

 

 

there is probably a faulty connection over the

 

long cable, or a bad RJ45 connection.

 

Insure that your load device works with an

 

802.3af compliant product (such as the

 

RBT-1002, RBT-1602, RBT-4102, and

 

RBT3K).

 

 

The Single-Port Power Over

Verify that the indicator for the port is “on.”

Ethernet Adapter operates and

Verify that the Single-Port Power Over

the load device works, but

Ethernet Adapter is connected to the Ethernet

there is no data link.

network with a good connection.

 

 

Verify that the Ethernet cable is Category 5 or

 

greater, and is less than 100 meters in length

 

from the Ethernet source to the load.

 

Try to connect a different device over the

 

same port. If it works and link is established,

 

there is probably a faulty data link in the load.

 

If possible, try to connect the load device into

 

a different unit. If it works, there is probably a

 

faulty output or input port in the Single-Port

 

Power Over Ethernet Adapter or a bad RJ45

 

connection.

3-2 Troubleshooting