Enterasys Networks BL-69108ENT, BL-69551ENT manual Troubleshooting Checklist

Models: BL-69551ENT BL-69108ENT

1 36
Download 36 pages 14.87 Kb
Page 29
Image 29

Checklist

Table 3-1 Troubleshooting Checklist (continued)

Problem

Recommended Action

 

 

The Single-Port Power Over Ethernet Adapter operates and the load device works, but there is no data link.

Verify that the indicator for the port is “on.”

Verify that the Single-Port Power Over Ethernet Adapter is connected to the Ethernet network with a good connection.

Verify that the Ethernet cable is Category 5 or greater, and is less than 100 meters in length from the Ethernet source to the load.

Try to connect a different device over the same port. If it works and link is established, there is probably a faulty data link in the load.

If possible, try to connect the load device into a different unit. If it works, there is probably a faulty output or input port in the Single-Port Power Over Ethernet Adapter or a bad RJ45 connection.

Single-Port Power Over Ethernet Adapter User’s Guide 3-3

Page 29
Image 29
Enterasys Networks BL-69108ENT, BL-69551ENT manual Troubleshooting Checklist