Connecting the PSM Cables and AC Power Cords

Connecting the PSM Cables and AC Power Cords

Connecting the PSM Cables and AC Power Cords

The PSMs are connected to the SecureStack C2 Ethernet switch devices using C2RPS‐PSM Cables.

To connect the PSMs, proceed as follows:

1.Connect one end of the C2RPS‐PSM Cable (shown in Figure 2‐3) to the Redundant Power Supply connector on the switch device. Then connect the other end to the Redundant Power Supply connector at the rear of the PSM as shown in Figure 2‐4 and Figure 2‐5.

2.Connect a standard AC power cord to the AC input power connector on the PSM shown in Figure 2‐4, then plug the AC power cord into the main AC power outlet.

3.The green Power LED on the front of the PSM will illuminate to indicate a successful connection. If the LED remains off, proceed as follows:

a.Check the AC power cord connection at the AC power source and make sure the power source is within specification.

b.Check the AC power connection to the PSM.

c.Swap the AC power cord with a known good one.

d.If the green LED continues to remain off, contact Enterasys Networks. Refer to Getting Help” on page 1‐5 for instructions. Otherwise, proceed to step 4.

4.If installing two PSM power supplies, repeat steps 1 through 3 for the second PSM.

Figure 2-3 C2RPS-PSM Cable

Figure 2-4 Power Connectors on C2RPS-PSM (rear view)

Redundant Power Supply

AC LINE

100-240 VAC

50-60 Hz

2A MAX

ÀÁ

1 Redundant Power Supply connector

2 AC power connector (rear of chassis)

2-6 Installation