Table 1-3 Minimum Revision of X Modules for DC Power

Model Name

Minimum 940 Part Number

Minimum 940 Revision

 

 

 

X-CM-00

4179

5A1

X-T32-00

4167

5A2

X-G32-00

4161

5A3

X-M2-00

4054

5H

 

 

 

X-M8-01

4162

5A

 

 

 

X-GT16-00

3977

5A

 

 

 

X16-FM

4059

5C

 

 

 

X8-FM

4055

5B

 

 

 

X4-FM

4050

5B

 

 

 

X-FAN

4085

5B

 

 

 

X-FAN-AC

N/A

N/A

1.Exception: If an X-CM-00 module meets the Minimum 940 Part Number revision and has a 2 digit 940 revision code of 4X (for example, 41, 42, and so on), the module is DC power- compliant.

2.Exception: If an X-T32-00 module meets the Minimum 940 Part Number revision and has a 2 digit 940 revision code of 4X (for example, 41, 42, and so on), the module is DC power- compliant.

3.Exception: If an X-G32-00 module meets the Minimum 940 Part Number revision and has a 2 digit 940 revision code of 4X (for example, 41, 42, and so on), the module is DC power- compliant.

Prepare Site Wiring for DC Power Installation

1.Ensure that a branch circuit disconnect device is installed, and that the device is switched to prevent power from being supplied to the DC power supply.

2.If desired, attach your wiring to the 2‐hole compression lugs provided.

For your convenience, Enterasys Networks ships with the DC power supply two 2‐hole compression lugs to which you can connect your wiring (6 AWG). These compression lugs are the correct size to fit over the positive and negative terminal studs. See Chapter 2, DC Power Supply Specifications for more details about the compression lugs.