Power Supply Redundancy

 

Table 2-3 Module Power Specifications

 

 

 

 

 

 

 

 

@ 48 VDC

 

 

 

 

 

Module

Power (Watts)

Thermal Output (BTU/HR)

 

 

 

 

 

CM

97 Watts

331.1 BTU/HR

 

 

 

 

 

Fan tray

85 Watts

290.1 BTU/HR

 

 

 

 

 

X4-FM

30 Watts

102.4 BTU/HR

 

 

 

 

 

X8-FM

62 Watts

211.6 BTU/HR

 

 

 

 

 

X16-FM

98 Watts

334.5 BTU/HR

 

 

 

 

 

X-GT16-00

155 Watts1

520.0 BTU/HR

 

X-T32-00

155 Watts

520.0 BTU/HR

 

 

 

 

 

X-G32-00

155 Watts

520.0 BTU/HR

 

 

 

 

 

X-M2-00

155 Watts

520.0 BTU/HR

 

 

 

 

 

X-M8-01

190 Watts

648.0 BTU/HR

1.The actual power draw of the X-GT16-00 is 105 Watts. However, for the purposes of budgeting the number of power supplies required, use 155 Watts.

Table 2-4 Redundancy Configurations for DC Power Supply

No. of Power Supplies

Max Redundant System Load 1

Redundancy Configuration

2

1500 Watts

1 + 1

 

 

 

3

3000 Watts

N + 1

 

 

 

4

3000 Watts

1 + 1

 

 

 

4

4500 Watts

N + 1

 

 

 

5

6000 Watts

N + 1

 

 

 

6

4500 Watts

1 + 1

 

 

 

6

6000 Watts

N + 1

1. The sum of individual power draws for all installed fan trays, control and fabric modules, and IOMs.

Matrix X Router DC Power Supply Installation Guide 2-3

Page 37
Image 37
Enterasys Networks CM Version 1.0 Module Power Specifications, Redundancy Configurations for DC Power Supply, @ 48 VDC