Enviro 50-1033 owner manual bottom, Initial Installation, Qualified Installers Only

Models: 50-1033

1 48
Download 48 pages 39.59 Kb
Page 20
Image 20
Notes:

Initial Installation

QUALIFIED INSTALLERS ONLY

HORIZONTAL INSTALLATION:

1.Set the appliance in the desired location. Check to determine if wall studs or roof rafters are in the way when the venting system is attached. If this is the case, you may want to adjust the location of

the appliance.

2.Direct vent pipe and fittings are designed with special twist-lock connections. Assemble the desired combination of black pipe and elbows to the appliance adapter with pipe seams oriented towards the wall or floor, as much out of view as possible.

Place a bead of Mil-Pac on the outer edge of the inner exhaust pipe (non-flared end). Place a bead of high temperature silicone on the male edge of the outer pipe. Push the pipe sections completely together, then twist-lock one section clockwise approximately 1⁄4 turn, until the two sections are fully locked. The female locking lugs will not be visible from the outside, on black pipe. They may be located by examining the inside of the female ends as shown in Figure 25.

Female

Locking

Lugs

Sealant

bottom.Manual backgroundMale

Manual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual background Locking

Lugs

Figure 25: Twist-Lock Connection

Notes:

 

 

 

 

 

 

 

(a) Twist-lock procedure: four (4) indentations, located on the female

10"

end of the pipes and fittings, are designed to slide straight onto the

(254mm)

male ends of adjacent pipes and fittings, by orienting the four pipe

 

indentations so they match and slide into the four entry slots on the

10"

male end.

 

 

 

 

 

 

 

 

 

 

 

 

(254mm)

(b) Horizontal runs of vent pipe must be supported every 36” (915mm).

 

Wall straps are available for this purpose, also when running horizontal

 

pipe

minimum

clearances

to

combustibles

must

be

maintained;

 

2” (51mm) at top, 11⁄2” (38mm) at sides, 11⁄2” (38mm) at

 

bottom.

 

 

 

 

 

 

 

3. With the pipe attached to the stove in the correct location, mark the

 

wall for a 10” (25.4cm) x 10” (25.4 cm) square hole (refer to Figure

 

26). The center of the square hole should match the center line of

Figure 26: Wall Framing Hole for

the horizontal pipe. Cut and frame the 10” (25.4cm) x 10” (25.4cm)

hole in the exterior wall where the vent will be terminated. Refer to

Horizontal Installation.

 

Figure 18. If the wall being

11/4"

 

 

 

 

penetrated is constructed of

 

 

 

 

non-combustible material i.e.

(3.2cm)

 

 

 

 

 

 

 

 

 

masonry or concrete, a 7”

Fold strap

 

 

 

Woodscrews

(17.8cm) hole is acceptable.

here

 

 

 

 

4. Position the horizontal vent

 

termination

in

the

center

Sheet metal

of

the

10”

(25.4cm)

x

10”

screws

(25.4cm)

hole,

and

attach

 

to

the

 

exterior

 

wall

with

 

the

four

screws

provided.

Wall Thimble

Before

attaching

the

 

vent

 

Strap

termination

to the exterior

Figure 27: Installing Decorative Wall Thimble.

 

 

 

 

 

 

 

 

 

20

Page 20
Image 20
Enviro 50-1033 owner manual bottom, Initial Installation, Qualified Installers Only