Initial Installation

QUALIFIED INSTALLERS ONLY

wall, run a bead of non-hardening mastic around the edges, so as to make a seal between the termination and the wall. The arrow on the vent termination should be pointing up, insure that the proper clearances to combustible materials are maintained.

5.Before connecting the horizontal run of the vent pipe to the vent termination, slide the black decorative wall thimble cover over the vent pipe.

6.Slide the appliance and vent assembly towards the wall, carefully inserting the vent pipe into the cap assembly. It is important that the vent pipe extend into the vent cap a sufficient distance with a minimum of 11⁄4” (3.2cm) overlap. Secure the connection between the vent cap pipe and the vent cap by attaching the two sheet metal straps extending from the vent cap assembly into the outer wall of the vent pipe. Use the two sheet metal screws provided to connect the straps to the vent pipe. Bend any remaining portion of the sheet metal straps back towards the vent cap, so the decorative wall thimble will conceal it (see left image in Figure 27).

7.Slide the decorative wall thimble up to the wall surface and attach with the screws provided. Apply decorative brass or chrome trim if desired (see right image in Figure 27).

NOTES:

(a)The four (4) wood screws provided should be replaced with the appropriate fasteners for stucco, brick, concrete, or other types of siding.

(b)For buildings with vinyl siding, a vinyl siding standoff, should be installed between the vent cap and the exterior wall (see Figure 28). Attach the vinyl siding standoff to the horizontal termination. The vinyl siding standoff prevents excessive heat from possibly melting the vinyl siding material. Note that the horizontal vent termination bolts onto the flat portion of the vinyl siding standoff (shaded area in Figure 28), so that an air space will exist between the wall and the vent termination.

(c)The horizontal run of vent pipe must be level and should have a 1⁄4 inch rise for every one foot of run towards the termination. Never allow the vent to run downward. This could cause high temperature and may present the possibility of a fire.

(d)The location of the horizontal vent termination on the exterior wall must not be easily blocked or

obstructed. Refer to INITIAL INSTALLATION - VENT CONFIGURATIONS AND RESTRICTOR SETTINGS.

(e)When installing a vent pipe in a chase the minimum clearance to combustibles is 2” (51 mm).

(f)Maintain manufacturer’s clearances to combustibles with venting.

Figure 28: Installing Vent Cap with Vinyl Siding

Figure 29: Installing Horizontal Vent

Stand-Off.

Termination.

21

Page 21
Image 21
Enviro 50-1033 owner manual Termination

50-1033 specifications

The Enviro 50-1033 is an innovative, environmentally-friendly vehicle designed to meet the growing demand for sustainable transportation solutions. As a part of the advanced Enviro series, the 50-1033 stands out due to its blend of efficiency, performance, and eco-conscious features.

One of the defining characteristics of the Enviro 50-1033 is its low-emission engine technology. The vehicle is equipped with a state-of-the-art diesel engine that adheres to stringent emission standards, significantly reducing pollutants compared to traditional models. This feature not only lessens the environmental footprint but also contributes to improved air quality in urban settings.

Additionally, the Enviro 50-1033 incorporates advanced fuel efficiency technologies, making it an economical choice for fleet operators. With a focus on maximizing fuel economy without compromising performance, this vehicle is designed to deliver cost savings over its lifecycle. The engine employs a combination of turbocharging and high-pressure fuel injection systems, which enhances combustion efficiency and maximizes power output while minimizing fuel consumption.

The vehicle’s design is another noteworthy aspect. Built with lightweight materials and aerodynamics that reduce drag, the Enviro 50-1033 enhances overall performance and maneuverability. The spacious interior is designed to accommodate a larger number of passengers without sacrificing comfort. Ergonomically designed seating and high-quality materials create an inviting atmosphere for both drivers and passengers.

Safety features are a top priority in the Enviro 50-1033. The vehicle is equipped with advanced driver assistance systems, including anti-lock braking systems, traction control, and electronic stability control. These technologies work together to enhance vehicle safety, providing peace of mind for operators and passengers alike.

The Enviro 50-1033 also offers modular design options, allowing customization to meet the specific needs of various transportation services. Whether for public transport, private hire, or shuttle services, the flexibility of the Enviro 50-1033 ensures that it can adapt to diverse operational demands.

In conclusion, the Enviro 50-1033 is a remarkable vehicle that embodies the future of sustainable transportation. With its cutting-edge technologies, eco-friendly features, and commitment to safety and comfort, it represents a significant step forward in the quest for greener urban mobility solutions. As cities globally embrace the transition to cleaner transportation options, the Enviro 50-1033 is well-positioned to play a vital role in shaping the future of public transport.