Enviro 50-1033 Wiring Diagram, General Venting Information, Canadian Installations

Models: 50-1033

1 48
Download 48 pages 39.59 Kb
Page 29
Image 29
INSTALLATION:

Initial Installation

QUALIFIED INSTALLERS ONLY

FREESTANDING DRAFTHOOD ADAPTOR - 50-841:

This Drafthood Adaptor is a complete assembly and is ready to fit onto your Westport in a vertical vent application only. With the Drafthood Adaptor correctly installed and wired to the gas control valve. Your Direct Vent Fireplace can be vented like a B-Vent Fireplace.

INSTALLATION:

WARNING: This Freestanding Drafthood Adaptor must be fitted by a qualified service technician.

1.Remove the Drafthood Adaptor from the packaging. Ensure the unit and wire harness are undamaged. If there is damage contact your dealer, distributor, or courier company before starting this installation.

2.Install the adaptor so the wires exit to the rear of the fireplace. Slide the Drafthood Adaptor over the outlet pipe of the fireplace until the bottom of the adaptor collar stops on the top of the outlet. The Drafthood Adaptor must be safely secured to the vent flanges with either self-tapping screws and/or high temperature sealant.

WARNING: During the fitting of the Drafthood Adaptor, ensure that the wires are not pinched between the adaptor and the collar and/or flue outlet. Ensure that the opening of the Drafthood Adaptor is not blocked or obstructed.

3.Being careful not to run any wiring tight across metal edges; connect them to the valve and “ON/OFF” switch (refer to Figure 45).

4. Adjust the restrictor plate

Optional remote

ON / OFF / Remote

Drafthood adaptor

to position 2.5 of 5. See the

300oF (149oC)

control receiver

thermostat switch

vent restrictor

settings in

 

 

manual reset

 

 

temperature

the instruction manual.

 

 

sensor

 

 

 

5. Adjust the embers on the

 

 

 

burner so they don’t cover

Purple

Grey

 

the burner ports.

 

Blue

 

WIRING DIAGRAM:

 

 

Grey

 

 

Grey

The fireplace

connections

 

 

 

 

 

are labelled in Figure 45.

 

 

 

When installing the Drafthood

 

 

 

Adaptor onto a fireplace fitted

 

Optional

 

with an optional wall switch or

 

 

 

wall switch

 

an optional thermostat, remove

 

 

 

one wire from the switch to

 

Optional

 

the gas valve and connect the

 

Valve

Drafthood Adaptor harness as

 

Thermostat

 

 

 

shown in Figure 45.

Figure 45: Wiring Diagram for Electrical Connection.

GENERAL VENTING INFORMATION:

Canadian Installations

The venting system must be installed in accordance with the current CSA B149 installation code and/or local codes having jurisdiction.

U.S.A. Installations

The venting system must be installed in accordance with the current National Fuel Gas Code, ANSI Z223.1, and/or local codes having jurisdiction.

29

Page 29
Image 29
Enviro 50-1033 owner manual Wiring Diagram, General Venting Information, Canadian Installations, U.S.A. Installations