Installation
•Follow vent manufacturer’s guidelines for installation of venting. High temperature sealant must be used when connecting the vent pipe to the unit’s starter pipe. Improper seals at the vent joints may cause combustion byproducts to leak into the room where installed - seal as required..
THROUGH WALL WITH VERTICAL RISE AND HORIZONTAL TERMINATION INSTALLATION- RECOMMENDED:
A 45° down elbow with a rodent screen may be used in place of the termination cap (or stainless steel termination hood).
���� �������
����������� ���
�������� ���� �������
�������� �������
�� ���� ����
���� �������
�� �
Figure 12: Venting horizontally with rise.
THROUGH CONCRETE WALL WITH VERTICAL RISE INSTALLATIONS:
A 45° down elbow with a rodent screen may be used in place of the termination cap (or stainless steel termination hood).
Installation to use if there is a concrete or retaining wall in line with exhaust vent on pellet stove.
The termination must be 305mm (12”) from the outside wall and 305mm (12”) above the ground.
Horizontal frame | Termination cap | |
for thimble | ||
| ||
Wall thimble |
| |
90o elbow |
| |
Wall framing |
| |
Vertical section |
| |
of vent pipe |
| |
| Concrete Wall | |
EF 5 | Clean out tee |
Figure 13: Venting with concrete wall behind unit .
14