Installation
CLEARANCES TO COMBUSTIBLES:
This unit can be installed on a combustible floor when installed with the optional hearth pad part
| Back Wall | 4" |
| 4" (10cm) | |
| (10cm) | |
Wall |
|
|
Side | 77/8" |
|
(20cm) |
| |
|
|
Figure 3: Evolution Clearance to Combustibles.
These dimensions are minimum clearances but it is recommended that you ensure sufficient room for servicing, routine cleaning and maintenance.
Side wall to unit | 200mm | (77⁄8 inches) |
Back wall to unit | 100mm | (4 inches) |
Corner to unit | 100mm | (4 inches) |
In Front of unit | 800mm | (311⁄2” inches) |
ALCOVE CLEARANCES:
This unit may be installed in an alcove. Maintain these clearances to combustibles.
Minimum Alcove width | 1220mm | (48 inches) |
Minimum Alcove height | 1220mm | (48 inches) |
Maximum Alcove depth | 1220mm | (48 inches) |
Install vent at clearances specified by the vent manufacturer.
48" |
(122cm) |
48" |
(122cm) |
48" |
(122cm) |
Figure 4: Evolution Minimum Alcove Size.
8