Installation

CLEARANCES TO COMBUSTIBLES:

This unit can be installed on a combustible floor when installed with the optional hearth pad part 50-1568 (for example linoleum, hardwood flooring). If this unit is to be installed onto a carpeted surface, a hearth pad must be used for stability.

 

Back Wall

4"

 

4" (10cm)

 

(10cm)

Wall

 

 

Side

77/8"

 

(20cm)

 

 

 

Figure 3: Evolution Clearance to Combustibles.

These dimensions are minimum clearances but it is recommended that you ensure sufficient room for servicing, routine cleaning and maintenance.

Side wall to unit

200mm

(77⁄8 inches)

Back wall to unit

100mm

(4 inches)

Corner to unit

100mm

(4 inches)

In Front of unit

800mm

(311⁄2” inches)

ALCOVE CLEARANCES:

This unit may be installed in an alcove. Maintain these clearances to combustibles.

Minimum Alcove width

1220mm

(48 inches)

Minimum Alcove height

1220mm

(48 inches)

Maximum Alcove depth

1220mm

(48 inches)

Install vent at clearances specified by the vent manufacturer.

48"

(122cm)

48"

(122cm)

48"

(122cm)

Figure 4: Evolution Minimum Alcove Size.

8

Page 8
Image 8
Enviro 50-1574 technical manual Minimum Alcove height 1220mm