Installation
TYPICAL THROUGH WALL WITH EXTERIOR BLOWER KIT INSTALLATION - HORIZONTAL TERMINATION:
EF 5
| 90° Elbow |
| 45°Elbow with Rodent |
| screen or stainless |
| steel termination hood |
| 2ft Riser |
| Pipe Adaptor |
Electrical Cable | Exterior Blower |
| and Housing |
Figure 20: Through Wall Installation with Exterior Blower Kit.
NOTE:
Ensure that all interior vent connections are sealed by placing a small bead of high temperature silicone around each chimney connection.
Also ensure that all vertical vent sections are properly supported and that all clearances to combustibles are maintained in accordance with the vent manufacturer’s specifications.
Wall Strap |
To supply power |
to the exhaust |
Figure 21: Through Wall Installation with Exterior Blower Kit; Side View.
Install an amour coated electrical cable from the exhaust blower housing, through the wall thimble plate and attach to the pre drilled hole in the left hand rear hopper pillar. Hook up to wires from the exhaust blower wiring harness.
All electrical connections must be in accordance to local code requirements
18