DIMENSIONS:

 

 

 

 

 

 

 

 

 

Unit Dimensions

 

 

 

 

 

Height:

840 mm

(33 1/16”)

 

 

 

 

Width:

565 mm

(22 1⁄4”)

 

 

 

27 7/8"

Depth:

539 mm

(21 1⁄4”)

 

 

 

(708 mm)

 

 

 

 

 

 

 

Hearth Pad:

 

IMPORTANT: When not installing

 

Width:

619 mm

(24 3⁄8”)

 

Depth:

708 mm

(27 7⁄8”)

the optional Hearth Pad on the

 

 

 

 

unit,

the minimum

requirements

24 3/8" (619 mm)

 

 

 

for

protection on

combustibles

 

21 1/4"

 

22 1/4" (565 mm)

 

 

floors are a width of 620mm

(539 mm)

 

 

 

 

 

(243⁄8”) & depth of 670mm

 

 

 

 

(263⁄8”) under the unit.

 

 

 

 

 

 

 

33 1/16"

 

 

5 13/16"

 

 

 

(840 mm)

 

 

(147 mm)

 

 

 

 

 

26 3/8" (670 mm)

 

 

 

Figure 1: Dimensions of Evolution.

 

Table 1: Evolution Specifications.

Classification

Testing Standard

Description

 

 

 

 

 

Class I IP-20

EN14785:2006/EN13240:2001/A2:2004

Residential Wood Pellet Heater

 

 

 

 

 

 

 

 

 

 

Voltage

Current

Frequency

 

 

 

 

 

220 - 240 V

2.0 - 2.3 Amps

50 Hz

 

 

 

 

 

 

 

 

 

 

Maximum Power Requirement

Fuel type

Calorific value of Pellet used

 

 

 

 

 

525W (1793 BTU/hr)

wood pellets - 6mm (1⁄4”) dia.

≥ 5.10 kWh/kg (≥ 7900 BTU/lb)

 

 

 

 

 

 

 

 

 

 

Maximum Flue Gas Temperature

Mean Flue Gas Temperature

Mean Flue Gas Temperature (Reduced)

 

 

 

 

 

200°C (392°F)

192°C (378°F)

143°C (289°F)

 

 

 

 

 

 

 

 

 

 

Nominal Heat Output

CO emissions from Combustion

Energy Efficiency

 

 

 

 

 

7.6 KWh (25932 BTU)

0.032%

 

 

84%

 

 

 

 

 

 

 

 

 

 

Reduced Heat Output

CO emissions from Combustion (Reduced Output)

Energy Efficiency (Reduced Output)

 

 

 

 

 

3.2 KWh (10919 BTU)

0.045%

 

 

75%

 

 

 

 

 

 

 

 

 

 

CO2 at Nominal Output

Nominal Fuel Consumption Rate

Unit with Full Hopper

8.35%

1.78 Kg/hr (3.95 lb/hr)*

~ 140kg (310lb)

 

 

 

 

 

CO2 at Reduced Output

Fuel Consumption Rate (Reduced Output)

Hopper Capacity

3.45%

0.83 Kg/hr (1.85 lb/hr)*

~ 40kg (90lb)

*Note: Consumption will vary with the type of fuel used.

7