To Install Panels:

Secondary Installation

OPTIONAL CERAMIC BRICK PANEL INSTALLATION:

Figure 41. Back Panel In Place.

Turn off the gas control knob and allow the unit to cool.

Please ensure that your ceramic panels have not been damaged.

To Install Panels:

1.Remove the glass door by following the

instruction in the “SECONDARY INSTALLATION -

GLASS DOOR REMOVAl” section and remove logs if necessary.

2.Slide center brick panel up behind the baffle (shown in Figure 41) and rest the bottom of the panel on the ledge.

3.Using a flat head screwdriver, bend the top tabs on either side at the front of the baffle down (refer to Figure 43 for placement).

4.Slide the right panel along the side of the firebox until it is tight against the right side of the center panel. Ensure the panel is behind the top tab (see Figure 42).

5.Bend up the right bottom tab until it touches the bottom of the right panel (see Figure 44) and press

the top right tab tight against the top of the panel (see Figure 43).

6.Repeat steps 4 and 5 for the left panel.

7.Install the log set (refer to SECONDARY INSTALLATION - LOG SET

AND EMBER INSTALLATION) and glass door.

To Remove Panels:

1.Pull the bottom and top tabs away from the side panels.

2.Carefully slide the side panels out towards the front, do not slide the panels on the tabs.

3.Push the center panel straight up about 1⁄4 inch (1⁄2 cm), pull the bottom out past the ledge, then pull the panel down until it

is past the bottom of the baffle. Remove panel from firebox

Figure 42. Right Panel In Place.

 

 

 

 

Figure 43. Top Tab For Right Panel.

 

Figure 44. Bottom Tab For Right Panel.