Trouble Shooting
Problem | Possible Cause | Solution |
Spark will not light the | Defective piezo ignitor | • Check connections to ignitor. |
pilot after repeatedly |
| • If ignitor connections are good but no spark, |
pressing the spark ignitor |
| replace ignitor. |
| Broken spark electrode | • Check for broken ceramic insulation, replace |
|
| electrode if broken. |
|
|
|
| Misaligned spark electrode | • If spark is not arcing from electrode to pilot, |
|
| loosen the screws on the pilot base adjust and |
|
| tighten. |
Pilot will not remain lit | Problem with | • Check for proper connection of the thermocouple |
| thermocouple circuit | to the rear of the valve. If loose, fully tighten. |
|
| • Check pilot for full flame impingement around |
|
| thermocouple. If flame is too small, check gas |
|
| pressure, adjust pilot rate screw, check pilot |
|
| head for damage. |
|
| • Check thermocouple voltage at valve. It |
|
| must be greater than 5 mV. If low, replace |
|
| thermocouple. |
| Air in gas line (pilot dies | • Bleed line. |
| while knob is depressed) | • Check gas line pressure. |
|
| • Contact dealer. |
Burners will not remain | Problem with thermopile | • Check gas line pressure . |
lit | circuit | • Check for flame impingement on thermopile. If |
|
| low, see “Pilot will not remain lit”. |
|
| • Check thermopile for minimum of 300 mV when |
|
| burner is switched on. |
|
| • Check wiring to thermostat for breaks. |
|
|
|
Flame lifting | Leak in vent pipe | • Check for leaks in vent connections. |
|
|
|
| Improper vent | • Check vent configuration with manual. |
| configuration |
|
| Terminal may be | • Check to see if terminal is on correctly. |
| recirculating flue gases | • May need to install high wind termination cap. |
|
| • Contact dealer. |
|
|
|
Glass fogs up | Normal Condition: after the appliance warms up the glass will clear. | |
| **Due to additives in gas, glass may get hazy during operation** Clean as | |
| needed. |
|
|
|
|
Blue Flames | Normal during start up: flames will yellow as the fireplace heats up. | |
Flames are burning | Flame impingement | • Check log positioning. |
“dirty” or sooting |
| • Increase primary air by opening the venturi |
|
| shutter and/or by opening the vent restrictor. |
|
| See also “Burners will not remain lit.” |
Remote control doesn’t | Problem with the remote | • One or more of the batteries are dead. See |
work |
| remote control instructions. |
| Problem with fireplace | • The on/off switch is turned to OFF. |
|
| • The gas control valve is turned to PILOT or OFF. |
|
| • The pilot has gone out. |
31