Trouble Shooting

Trouble Shooting

Problem

Possible Cause

Solution

Spark will not light the

Defective piezo ignitor

• Check connections to ignitor.

pilot after repeatedly

 

• If ignitor connections are good but no spark,

pressing the spark ignitor

 

replace ignitor.

 

Broken spark electrode

• Check for broken ceramic insulation, replace

 

 

electrode if broken.

 

 

 

 

Misaligned spark electrode

• If spark is not arcing from electrode to pilot,

 

 

loosen the screws on the pilot base adjust and

 

 

tighten.

Pilot will not remain lit

Problem with

• Check for proper connection of the thermocouple

 

thermocouple circuit

to the rear of the valve. If loose, fully tighten.

 

 

• Check pilot for full flame impingement around

 

 

thermocouple. If flame is too small, check gas

 

 

pressure, adjust pilot rate screw, check pilot

 

 

head for damage.

 

 

• Check thermocouple voltage at valve. It

 

 

must be greater than 5 mV. If low, replace

 

 

thermocouple.

 

Air in gas line (pilot dies

• Bleed line.

 

while knob is depressed)

• Check gas line pressure.

 

 

• Contact dealer.

Burners will not remain

Problem with thermopile

• Check gas line pressure .

lit

circuit

• Check for flame impingement on thermopile. If

 

 

low, see “Pilot will not remain lit”.

 

 

• Check thermopile for minimum of 300 mV when

 

 

burner is switched on.

 

 

• Check wiring to thermostat for breaks.

 

 

 

Flame lifting

Leak in vent pipe

• Check for leaks in vent connections.

 

 

 

 

Improper vent

• Check vent configuration with manual.

 

configuration

 

 

Terminal may be

• Check to see if terminal is on correctly.

 

recirculating flue gases

• May need to install high wind termination cap.

 

 

• Contact dealer.

 

 

 

Glass fogs up

Normal Condition: after the appliance warms up the glass will clear.

 

**Due to additives in gas, glass may get hazy during operation** Clean as

 

needed.

 

 

 

 

Blue Flames

Normal during start up: flames will yellow as the fireplace heats up.

Flames are burning

Flame impingement

• Check log positioning.

“dirty” or sooting

 

• Increase primary air by opening the venturi

 

 

shutter and/or by opening the vent restrictor.

 

 

See also “Burners will not remain lit.”

Remote control doesn’t

Problem with the remote

• One or more of the batteries are dead. See

work

 

remote control instructions.

 

Problem with fireplace

• The on/off switch is turned to OFF.

 

 

• The gas control valve is turned to PILOT or OFF.

 

 

• The pilot has gone out.

31